Water Supply Connection - Kenmore Ice maker Use And Care Manual

Hide thumbs Also See for Ice maker:
Table of Contents

Advertisement

Available languages

Available languages

Recommended
grounding
method
For your personal safety, this appliance must be grounded. This
appliance is equipped with a power supply cord having a 3 prong
grounding plug. To minimize possible shock hazard, the cord
must be plugged into a mating, 3 prong, grounding-type
wall
receptacle, grounded in accordance
with the National Electrical
Code and local codes and ordinances.
If a mating wall receptacle
is not available, it is the personal responsibility
of the customer to
have a properly grounded, 3 prong wall receptacle installed by a
qualified electrician.
It is important for the ice maker to be level in order to work
properly. Depending upon where you install the ice maker, you
may need to make several adjustments to level it. You may also
use the leveling legs to lower the height of the ice maker for
undercounter
installations.
Tools required
Carpenter's level
Adjustable wrench
NOTE: It is easier to adjust the leveling legs if you have another
person to assist you.
1. Place a carpenter's level on top of the product to see if the ice
maker is level from front to back and side to side.
2. Push up on the top front of the ice maker, and then locate the
leveling screws that are on the bottom front of the ice maker.
3. Using an adjustable wrench, change the height of the legs as
follows:
Turn the leveling leg to the right to lower that side of the
ice maker.
Turn the leveling leg to the left to raise that side of the ice
maker.
NOTE: The ice maker should not wobble. Use shims to add
stability when needed.
4. Push up on the top rear of the ice maker and locate the
leveling legs that are on the bottom rear of the ice maker.
5. Follow the instructions
in Step 3 to change the height of the
legs.
6. Use a carpenter's
level to recheck the ice maker to see that it
is even from front to back and side to side. If the ice maker is
not level, repeat Steps 2-5. If the ice maker is level, go to the
"Water Supply Connection"
section.
Read all directions
carefully before you begin.
IMPORTANT:
Plumbing shall be installed in accordance
with the
International
Plumbing Code and any local codes and
ordinances.
Use copper tubing and check for leaks.
Install copper tubing only in areas where temperatures
will
remain above freezing.
Tools required
Flat-blade screwdriver
7/16"and 1/2"open-end wrenches or 2 adjustable wrenches
1/4"nut driver
1/4"drill bit
Hand drill or electric drill properly grounded
NOTE: Your ice maker dealer has a kit available with a 1/4"
(6.35 mm) saddle-type
shutoff valve, a union, and copper tubing.
Before purchasing, make sure a saddle-type
valve complies with
your local plumbing codes. Do not use a piercing-type
or 3/16"
(4.76 mm) saddle valve which reduces water flow and clogs more
easily.
Connecting
the water
line
1.
2.
Turn off main water supply. Turn on nearest faucet long
enough to clear line of water.
Find a 1/2"(12.70 mm) to 11/4 '' (3.18 cm) vertical cold water
pipe near the ice maker.
NOTE: Horizontal pipe will work, but the following procedure
must be followed: Drill on the top side of the pipe, not the
bottom. This will help keep water away from the drill. This
also keeps normal sediment from collecting in the valve.
3. Using a grounded drill, drill a 1/4"(6.35 mm) hole in the cold
water pipe you have selected.
4. Fasten shutoff valve to cold water pipe with pipe clamp. Be
sure outlet end is solidly in the 1/4"(6.35 mm) drilled hole in the
water pipe and that washer is under the pipe clamp. Tighten
packing nut. Tighten the pipe clamp screws carefully and
evenly so washer makes a watertight seal. Do not overtighten
the pipe clamp or you may crush cold water pipe if it is soft
copper tubing. Do not use a piercing-type
or 3/16"(4.76 mm)
saddle-type
valve which reduces water flow and clogs more
easily.
5. Now you are ready to connect the copper tubing. Use 1/4"
(6.35 mm) OD soft copper tubing for the cold water supply.
Ensure that you have the proper length needed for the
job. Be sure both ends of the copper tubing are cut
square.
Slip compression
sleeve and compression
nut on copper
tubing as shown. Insert end of tubing into outlet end
squarely as far as it will go. Screw compression
nut onto
outlet end with adjustable wrench. Do not overtighten.
.................... A
H
..........
....................
B
A. Cold water pipe
E.Compression nut
B. Pipe clamp
E Compression sleeve
C. Copper tubing
G.Shutoff valve
D. Coupling (purchased)
H. Packing nut
Place the free end of the tubing into a container or sink, and
turn on main water supply and flush out tubing until water is
clear. Turn off shutoff valve on the water pipe.
NOTE: Always drain the water line before making the final
connection to the inlet of the water valve to prevent possible
water valve malfunction.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents