COOLING, HEATING, AUTOMATIC, FAN,
AND PROGRAM DRY OPERATION
Operate in the following order.
OPERATION MODE SELEC-
1
TOR
Press OPERATION MODE SELECTOR but-
ton several times and select the OPERA-
TION MODE of your choice as follows.
COOLING OPERATION ........................ "
HEATING OPERATION ......................... "
AUTOMATIC OPERATION .................... "
• In this operation mode,COOL/HEAT
changeover is automatically conducted.
FAN OPERATION ................................. "
DRY OPERATION ................................. "
• The function of this program is to decrease
the humidity in your room with the minimum
temperature decrease.
• Micro computer automatically determines
TEMPERATURE and FAN SPEED.
• This system dose not go into operation if the
room temperature is below 16
Refer to figure 3 on page
• For cooling only type, " COOLING ", " FAN " and
" DRY " operation are able to select.
2
ON/OFF
Press ON/OFF button
OPERATION lamp lights up or goes off and the sys-
tem starts or stops OPERATION.
[EXPLANATION OF HEATING OPERATION]
(1) DEFROST OPERATION
• As the frost on the coil of an outdoor unit
increase, heating effect decreases and the
system goes into DEFROST OPERATION.
• The indoor unit fan stops and the remote con-
troller display shows"
• After 6 to 8 minutes (maximum 10 minutes) of
DEFROST OPERATION, the system returns
to HEATING OPERATION.
(2) HOT START
• In order to prevent cold air from blowing out of
an indoor unit at the start of heating operation,
the indoor fan is automatically stopped. The
display of the remote controller shows
"
" (DEFROST/HOT START).
English
"
"
"
"
"
°
C.
[1]
".
(3) OPERATION START
• For ordinary heating, it will take longer for the
room temperature to reach the set tempera-
ture than with cooling. We therefore recom-
mend starting the unit ahead of time using the
timer operation.
Regarding outside air temperature and
heating capacity
• The heating capacity of the air conditioner
declines as the outside air temperature falls.
In such a case, use the air conditioner in combi-
nation with other heating systems.
• A warm air circulating system is employed, and
therefore it takes some time until the entire room
is warmed up after the start of operation.
• An indoor fan runs to discharge a gentle wind
automatically until the temperature inside the air
conditioner reaches a certain level. At this time,
the remote controller displays"
as it stands and wait for a while.
• When the warm air stays under the ceiling and
your feet are cold, we recommend that you use a
circulator (a fan to circulate the air inside the
room). For details,consult your dealer.
ADJUSTMENT
For programming TEMPERATURE, FAN SPEED
and AIR FLOW DIRECTION, follow the procedure
shown below.
TEMPERATURE SETTING
Press TEMPERATURE SETTING button and
program the setting temperature.
Each time this button is pressed,setting
temperature rises 1
Each time this button is pressed, set-
ting temperature lowers 1
• The setting is impossible for fan operation.
NOTE
• The setting temperature range of the remote con-
°
°
troller is 16
C to 32
FAN SPEED CONTROL
Press FAN SPEED CONTROL button.
High or Low fan speed can be selected.
Micro computer may sometimes control the fan
speed in order to protect the unit.
". Leave it
°
C.
°
C.
C.