Section 2: L-3 Stormscope Interface; L-3 Stormscope Description; Power-Up Self-Test; User-Initiated Test - Garmin 400W Series Pilot's Manual Addendum

400w series 500w series display interfaces
Hide thumbs Also See for 400W Series:
Table of Contents

Advertisement

Section 2
L-3 Stormscope Interface

SECTION 2: L-3 STORMSCOPE INTERFACE

L-3 STORMSCOPE Description

NOTE: Refer to the WX-500 Pilot's Guide for a detailed
description of the WX-500 STORMSCOPE.
The L-3 STORMSCOPE WX-500 Weather Map-
ping Sensor is a passive weather avoidance system
that detects electrical discharges associated with
thunderstorms within a 200-NM radius of the aircraft.
The STORMSCOPE measures relative bearing and
distance of thunderstorm-related electrical activity and
reports the information to the display. Interfaces are
currently only available for the WX-500 STORM-
SCOPE System.
The 400W/500W Series units perform a self-
test during power-up to ensure proper opera-
tion of the applicable interface components.

Power-Up Self-Test

The power-up self-test ensures that the WX-500
functions are operating properly. An error message
is displayed on the Message Page if data is no longer
being received.
4

User-Initiated Test

In addition to the power-up test, the WX-500 per-
forms a continuous self-test. This continuous self-test
is performed several times per minute. A user-initiated
test can also be performed. The WX-500 Pilot' s Guide
lists all of the possible faults, probable causes, and
recommended actions if system failures are noted.
In addition to the power-up test, the user can
perform a self-test that is executed through
the 400W/500W Series unit display.
To perform a user-initiated test:
From the default Nav Page, turn the small
1.
right knob to select the Lightning (LTNG)
Page.
Press MENU to display the Page Menu.
2.
Turn the small right knob to select "Self-
3.
Test?" and press ENT.
190-00356-31 Rev. C

Advertisement

Table of Contents
loading

Table of Contents