Installation
Instructions
CONNECTING
THE DRYER TO HOUSE VENT
{CONT.)
UL-Listed Flexible Metal (Foil-Type)Transition Duct
• In special installations, it meg be necessary to connect
the dryer to the house vent using e flexible metal
(foil-type) duct. A UL-listed flexible metal (foil-type) duct
meg be used ONLYin installations where rigid metal
or flexible metal (semi-rigid) ducting cannot be used
AND where a 4" diameter can be maintained
throughout the entire length of the transition duct.
In Canada end the United States, only the flexible
metal (foil-type) ducts that comply with the "Outline for
Clothes Dryer Transition Duct, Subject 2158A" shell be
used.
• Never install flexible metal duct in wells, ceilings, floors
or other enclosed spaces.
Total length of flexible metal duct should not exceed
8 feet (2.4 m).
• Avoid resting the duct on sharp objects.
For best drying performance:
1. Slide one end of the duct over the clothes dryer outlet
pipe.
2. Secure the duct with e clamp.
5. With the dryer in its permanent position, extend the
duct to its full length. Allow 2" of duct to overlap the
exhaust pipe. Cut off end remove excess duct. Keep
the duct us straight us possible for maximum airflow.
4. Secure the duct to the exhaust pipe with the other
clamp.
SEALING
OF JOINTS
• All joints should be tight to ovoid leeks.
NOTE: T he mule end of each section of duct must point
away from the dryer.
Do not assemble ductwork with fasteners that
extend into the duct. They will serve as e collection
point for lint.
Duct joints can be made air- end moisture-tight by
wrapping the overlapped joints with duct tape.
INSULATION
• Ductwork that runs through an unheated area or
is near an air conditioning duct should be insulated
to reduce condensation end lint buildup.
PARTS AVAILABLE
FROM LOCAL SERVICE
ORGANIZATIONS
• Rigid Metal Duct Components
WX8X65
a" x 1' Duct
WX8X64
4" x 2' Duct
WX8X51
4" Elbow
WX8X59
4" Aluminum Hood
• Flexible Metal Duct Components
WX8X58
4" Clamps (2)
WX8X59
4" Aluminum Hood
WX08X10077
6' UL-Listed, Flexible Metal (Semi-Rigid)
Duct, 2 Clamps, 2 Close Elbows
MOBILE HOME INSTALLATION
• Installation must conform to Manufactured Home
Construction and Safety Standard, Title 24 CFR,
Part 32-80.
The dryer must be exhausted to the outside with
the termination securely fastened to the mobile
home structure.
The exhaust MUSTNOT be terminated beneath the
mobile home.
The exhaust duct material MUSTNOT support
combustion.
CONSIDERATION MUST BEGIVEN TO PROVIDEADEQUATE
CLEARANCES FOR INSTALLATION AND SERVICE.
ALCOVE OR CLOSET INSTALLATION
i Ir
60 Sq.In.
60 Sq. In.
"--
_
0 ......
O"
• If your dryer is approved
for installation
in on alcove
or closet, it will be stoted on o Iobel on the bock of
the dryer.
TO PREVENT LARGE AMOUNTS OF LINT AND MOISTURE
FROM ACCUMULATING AND TO MAINTAIN DRYING
EFFICIENCY, THIS MACHINE MUST BE EXHAUSTED
OUTDOORS.
• DO NOT instoll this opplionce with less thon
the minimum cleoronces shown obove.
CONSIDERATION MUST BE GIVEN TO PROVIDE ADEQUATE
CLEARANCES FOR INSTALLATION AND SERVICE.
CAUTION:
DO NOT INSTALL THIS APPLIANCE
IN A CLOSET WITH A SOLID DOOR.