Download Print this page

GE 31-16223 Installation Manual page 4

Comercial stacked gas dryers

Advertisement

m
GAS CONNECTION
RECONNECTING GAS
Listed connector
ANSI
Z21.24
/ CSA 6.10
118" NPT PIPE
NEWMETAL
PLUG FOR
GAS
FLEXIBLE GAS
INLET PRESSURE
LINECONNECTOR
ADAPTER
ELBOW
318" NPT
SHUT-OFF
PIPE SIZE
ITEMSNOT SUPPLIED
AT LEAST 1/2"
Note: The connector and fittings ore designed for use only
on the original installation and are not to be reused for
another appliance or at another location. Keepflare end of
adaptor free of grease, oil and thread sealant.
Caution: Useadapters as shown. Connector nuts must not
be connected directly to pipe threads.
APPLYPIPECOMPOUND
TO THEADAPTERAND
DRYER GAS INLET.
Tighten the flexible
gas line using two
adjustable wrenches.
INFORMATION
(continued)
APPLYPiPECOMPOUND
TOALL MALETHREADS.
/
Tighten all connections using two adjustable wrenches.
Do not overtorque gas connections!
[]
LEAKTEST
A_, WARNING- NEVER USE AN OPEN
FLAMETO TEST FORGAS LEAKS.
OPEN
GASVALVE.
Check olt connections
for leaks with soapg solution or equivalent.
Applg soap solution.
Leak test solution must not contain
ammo-
nia which could cause damage
to the brass fittings.
If leaks are
found, dose valve, retighten the joint, and repeat the soap test.