25HCB3
Comfortt 13 Series Heat Pump
with Puronr Refrigerant
1---1/2 To 5 Nominal Tons (Sizes 18 To 60)
the environmentally sound refrigerant
Carrier's heat pumps with Puronr refrigerant provide a collection
of features unmatched by any other family of equipment. The
25HCB3 has been designed utilizing Carrier's Puron refrigerant.
The environmentally sound refrigerant allows consumers to make
a responsible decision in the protection of the earth's ozone layer.
This product has been designed and manufactured to meet
Energy Starr criteria for energy efficiency when matched with
appropriate coil components. Refer to the combination ratings in
the Product Data for system combinations that meet Energy Starr
guidelines.
NOTE: Ratings contained in this document are subject to
change at any time. Always refer to the AHRI directory
(www.ahridirectory.org) for the most up- -to- -date ratings
information.

Product Data

INDUSTRY LEADING
FEATURES / BENEFITS
Efficiency
Sound
Comfort
Reliability
Durability
WeatherArmort protection package:
Applications
S
S
S
13 SEER/ 10.1 - - 10.8 EER/ 7.7 - - 8.3 HSPF (Nominal)
S
Microtube Technologyt refrigeration system
S
Indoor air quality accessories available
S
Sound level as low as 70 dBA
S
System supports Thermidistatt or standard thermostat
controls
Puronr refrigerant - - environmentally sound, won't
S
deplete the ozone layer and low lifetime service cost.
S
Front- -seating service valves
S
Scroll compressor
S
Internal pressure relief valve
S
Internal thermal overload
S
High pressure switch
S
Loss of charge switch
S
Filter drier
Balanced refrigeration system for maximum reliability
S
S
Solid, durable sheet metal construction
Steel louver coil guard
S
S
Ceramic coated cabinet screws
S
Baked- -on, complete coverage, powder paint
Long- -line - - up to 250 feet (76.20 m) total equivalent length,
up to 200 feet (60.96 m) condenser above evaporator, or up to
80 ft. (24.38 m) evaporator above condenser (See Longline
Guide for more information.)
Low ambient (down to - -20_F/- -28.9_C) with accessory kit

Advertisement

Table of Contents
loading

Summary of Contents for Carrier 25HCB3

  • Page 1: Product Data

    Loss of charge switch Filter drier Balanced refrigeration system for maximum reliability Carrier’s heat pumps with Puronr refrigerant provide a collection Durability of features unmatched by any other family of equipment. The 25HCB3 has been designed utilizing Carrier’s Puron refrigerant.
  • Page 2: Model Number Nomenclature

    MODEL NUMBER NOMENCLATURE Product Product Major Cooling Minor Tier SEER Variations Open Open Voltage Series Family Series Capacity Series 3=208/230 ---1 0=Not 0=Not 5=208/230 ---3 25 = HP H = RES HP C=Comfort B = Puron 3=13 SEER A = Standard 0, 1, 2...
  • Page 3: Physical Data

    PHYSICAL DATA UNIT SIZE --- SERIES, VOLTAGE 18--- 30 24--- 30 30--- 30 36--- 30 42--- 30 48--- 30 60--- 31 Operating Weight lb (kg) (78.9) (83.0) (93.4) (92.1) (119.32) (128.4) (135.6) Shipping Weigh lb (kg) (91.2) (95.3) (106.6) (109.3) (133.8) (142.0) (150.1)
  • Page 4 * Do not use in zoning heat pump applications. ** Outdoor temperature sensor is an accessory for all Carrier electronic thermostats, except the non ---programmable air conditioner version and builder;s thermostats. It allows the temperature at a remote location (outdoors) to be displayed on the thermostat. The outdoor air temperature sensor must be used with the HybridHeatt (dual fuel) thermostat.
  • Page 5 ACCESSORY USAGE GUIDELINE REQUIRED FOR LOW --- AMBIENT REQUIRED FOR REQUIRED FOR Accessory COOLING APPLICATIONS LONG LINE APPLICATIONS* SEA COAST APPLICATIONS (Below 55°F / 12.8°C) (Over 80 ft. / 24.38 m) (Within 2 miles / 3.22 km) Accumulator Standard Standard Standard Ball Bearing Fan Motor Yes{...
  • Page 6 Accessory Description and Usage (Listed Alphabetically) - - CONTINUED 10. Outdoor Air Temperature Sensor 14. Sound Hood Designed for use with Carrier Thermostats listed in this Wraparound sound reducing cover for the compressor. Reduces publication. This device enables the thermostat to display the the sound level by about 2 dBA.
  • Page 7: Electrical Data

    ELECTRICAL DATA FUSE** UNIT SIZE --- OPER VOLTS* COMPR WIRE WIRE LENGTH LENGTH V/PH or CKT SERIES, SIZE† SIZE† ft (m)‡ ft (m)‡ VOLTAGE 60° C 75° C 60° C 75° C AMPS 18--- 30 48.0 11.9 66 (20.1) 62 (18.9) 24--- 30 58.3 12.8...
  • Page 11 Wall...
  • Page 12 COMBINATION RATINGS High Temp Low Temp AHRI Ref. Model Furnace Model Cooling Coil Model Number SEER HSPF Number Number Capacity E COP H COP Capacity Capacity 3850430 25HCB318A30 †FB4CNF018 17200 11.0 13.0 17,400 3.60 10,200 2.34 3684925 25HCB318A30 FB4CNF018+TXV 17400 11.5 14.5 17,700...
  • Page 13: Combination Ratings Continued

    COMBINATION RATINGS CONTINUED High Temp Low Temp AHRI Ref. Model Furnace Model Cooling Coil Model Number SEER HSPF Number Number Capacity E COP H COP Capacity Capacity 3033411 25HCB318A30 CSPH*2412A** 58CV(A,X)070---12 17300 12.0 14.5 17,400 3.52 10,100 2.32 3033412 25HCB318A30 CSPH*2412A** 58CV(A,X)090---16 17400...
  • Page 14 COMBINATION RATINGS CONTINUED High Temp Low Temp AHRI Ref. Model Furnace Model Cooling Coil Model Number SEER HSPF Number Number Capacity E COP H COP Capacity Capacity 3684929 25HCB324A30 CNPH*2417A** 58HDV040--- ---12 22400 11.2 13.5 23,800 3.70 14,600 2.58 3684930 25HCB324A30 CNPH*2417A** 58HDV060--- ---12...
  • Page 15 COMBINATION RATINGS CONTINUED High Temp Low Temp AHRI Ref. Model Furnace Model Cooling Coil Model Number SEER HSPF Number Number Capacity E COP H COP Capacity Capacity 4209707 25HCB324A30 CNPV*3017A** OVMAAB036098 22800 12.0 14.5 23,000 3.72 14,500 2.60 4209709 25HCB324A30 CNPV*3017A** OVMAAB042112 22800...
  • Page 16 COMBINATION RATINGS CONTINUED High Temp Low Temp AHRI Ref. Model Furnace Model Cooling Coil Model Number SEER HSPF Number Number Capacity E COP H COP Capacity Capacity 3121395 25HCB330A30 CAP**3017A** 58ME(B,C)060---12 30000 11.5 14.0 30,000 3.60 18,100 2.48 3121396 25HCB330A30 CAP**3017A** 58ME(B,C)080---12 30000...
  • Page 17 COMBINATION RATINGS CONTINUED High Temp Low Temp AHRI Ref. Model Furnace Model Cooling Coil Model Number SEER HSPF Number Number Capacity E COP H COP Capacity Capacity 3685031 25HCB330A30 CNPH*3117A** 58CV(A,X)135---22 30000 12.0 14.5 30,000 3.68 18,000 2.54 3685032 25HCB330A30 CNPH*3117A** 58CV(A,X)155---22 30000...
  • Page 18 COMBINATION RATINGS CONTINUED High Temp Low Temp AHRI Ref. Model Furnace Model Cooling Coil Model Number SEER HSPF Number Number Capacity E COP H COP Capacity Capacity 4209737 25HCB330A30 CNPV*3117A** OVLAAB036098 30000 11.5 14.5 30,000 3.66 18,200 2.50 4209736 25HCB330A30 CNPV*3117A** OVMAAB036098 30000...
  • Page 19 COMBINATION RATINGS CONTINUED High Temp Low Temp AHRI Ref. Model Furnace Model Cooling Coil Model Number SEER HSPF Number Number Capacity E COP H COP Capacity Capacity 3033603 25HCB330A30 CSPH*3612A** 58CV(A,X)135---22 30000 12.0 14.0 30,000 3.64 18,000 2.50 3033604 25HCB330A30 CSPH*3612A** 58CV(A,X)155---22 30000...
  • Page 20 COMBINATION RATINGS CONTINUED High Temp Low Temp AHRI Ref. Model Furnace Model Cooling Coil Model Number SEER HSPF Number Number Capacity E COP H COP Capacity Capacity 3121431 25HCB336A30 CAP**4221A** 58ME(B,C)100---20 34400 11.5 14.5 34,400 3.72 20,800 2.60 3033730 25HCB336A30 CAP**4221A** 58CV(A,X)110---20 34200...
  • Page 21 COMBINATION RATINGS CONTINUED High Temp Low Temp AHRI Ref. Model Furnace Model Cooling Coil Model Number SEER HSPF Number Number Capacity E COP H COP Capacity Capacity 3033765 25HCB336A30 CNPH*4221A** 58MV(B,C)080---20 34000 11.5 14.0 34,400 3.64 21,000 2.54 3033766 25HCB336A30 CNPH*4221A** 58MV(B,C)100---20 34000...
  • Page 22 COMBINATION RATINGS CONTINUED High Temp Low Temp AHRI Ref. Model Furnace Model Cooling Coil Model Number SEER HSPF Number Number Capacity E COP H COP Capacity Capacity 4209784 25HCB336A30 CNPV*3621A** OVLAAB048112 33600 11.2 13.5 34,600 3.60 21,200 2.50 3033739 25HCB336A30 CNPV*3621A**+TDR 33800 10.8...
  • Page 23 COMBINATION RATINGS CONTINUED High Temp Low Temp AHRI Ref. Model Furnace Model Cooling Coil Model Number SEER HSPF Number Number Capacity E COP H COP Capacity Capacity 3033779 25HCB336A30 CSPH*3612A** 58MV(B,C)100---20 34600 11.5 14.0 34,400 3.72 21,000 2.58 3033780 25HCB336A30 CSPH*3612A** 58MV(B,C)120---20 34400...
  • Page 24 COMBINATION RATINGS CONTINUED High Temp Low Temp AHRI Ref. Model Furnace Model Cooling Coil Model Number SEER HSPF Number Number Capacity E COP H COP Capacity Capacity 3034071 25HCB342A30 CAP**4221A** 58MV(B,C)080---14 39500 10.9 13.5 41,500 3.42 25,400 2.46 3034072 25HCB342A30 CAP**4221A** 58MV(B,C)080---20 40000...
  • Page 25 COMBINATION RATINGS CONTINUED High Temp Low Temp AHRI Ref. Model Furnace Model Cooling Coil Model Number SEER HSPF Number Number Capacity E COP H COP Capacity Capacity 3034181 25HCB342A30 CNPH*4221A** 58PH*090---16 40000 11.2 13.5 41,000 3.52 25,200 2.52 3034182 25HCB342A30 CNPH*4221A** 58PH*110---20 40000...
  • Page 26 COMBINATION RATINGS CONTINUED High Temp Low Temp AHRI Ref. Model Furnace Model Cooling Coil Model Number SEER HSPF Number Number Capacity E COP H COP Capacity Capacity 3034167 25HCB342A30 CNPV*4221A** 58CV(A,X)090---16 40500 11.5 14.0 41,500 3.44 25,600 2.42 3034097 25HCB342A30 CNPV*4221A** 58CV(A,X)110---20 40000...
  • Page 27 COMBINATION RATINGS CONTINUED High Temp Low Temp AHRI Ref. Model Furnace Model Cooling Coil Model Number SEER HSPF Number Number Capacity E COP H COP Capacity Capacity 3034139 25HCB342A30 CSPH*4212A** 58MV(B,C)120---20 40000 11.4 14.0 41,000 3.62 25,400 2.56 3034188 25HCB342A30 CSPH*4212A** 58PH*070---16 41000...
  • Page 28 COMBINATION RATINGS CONTINUED High Temp Low Temp AHRI Ref. Model Furnace Model Cooling Coil Model Number SEER HSPF Number Number Capacity E COP H COP Capacity Capacity 3757499 25HCB348A30 CAP**4824A** 58UVB120---20 45500 11.5 14.0 48,000 3.64 29,600 2.60 3034479 25HCB348A30 CAP**4824A**+TDR 46000 10.8...
  • Page 29 COMBINATION RATINGS CONTINUED High Temp Low Temp AHRI Ref. Model Furnace Model Cooling Coil Model Number SEER HSPF Number Number Capacity E COP H COP Capacity Capacity 3685234 25HCB348A30 CNPV*4821A** 58VMR120---20 45500 11.5 14.0 48,000 3.58 29,600 2.60 4209860 25HCB348A30 CNPV*4821A** OVLAAB048112 45500...
  • Page 30 COMBINATION RATINGS CONTINUED High Temp Low Temp AHRI Ref. Model Furnace Model Cooling Coil Model Number SEER HSPF Number Number Capacity E COP H COP Capacity Capacity 3286562 25HCB360A31 CAP**6024A** 58CV(A,X)155---22 59000 11.5 14.0 57,500 3.54 35,800 2.56 3286575 25HCB360A31 CAP**6024A** 58ME(B,C)120---20 58000...
  • Page 57 GUIDE SPECIFICATIONS AIR- -COOLED, SPLIT- -SYSTEM HEAT PUMP 25HCB3 GENERAL 1- -1/2 TO 5 NOMINAL TONS System Description Fans Outdoor- -mounted, air- -cooled, split- -system heat pump unit — Condenser fan will be direct- -drive propeller type, suitable for ground or rooftop installation. Unit consists of a discharging air upward.
  • Page 58 Catalog No. 25HCB3---4PD Copyright 2010 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 10/10 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Table of Contents