Troubleshooting (cont.)
Problem
Overheating
1. Air filters need cleaning/replacing.
2. Unusually dusty environment.
3. Extension cord used.
4. Unit not on level surface.
Compressor
1. Loose fittings.
starts and stops
excessively
2. Compressor not large enough for job.
Excessive noise
1. Loose or damaged belt guard.
2. Loose fittings.
3. Unit not on level surface.
Moisture in
Too much moisture in air.
discharge air
Safety Valve "pops"
Safety valve needs service.
Air leaks from
Loose fittings.
pump or fittings
Air leaks from tank
Defective or rusted tank.
Follow all safety precautions whenever diagnosing or servicing the compressor.
Disconnect power supply before service.

PLEASE READ THE FOLLOWING CAREFULLY

THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM
IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR DISTRIBUTOR
MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS
QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS QUALIFIED TO REPLACE
ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER AND/OR DISTRIBUTOR EXPRESSLY
STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND
LICENSED TECHNICIANS, AND NOT BY THE BUYER. THE BUYER ASSUMES ALL RISK AND LIABILITY
ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS
THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO.
Item 69666
69669
Possible Causes
For technical questions, please call 1-800-444-3353.
Likely Solutions
1. Check inlet and outlet filters.
Clean and/or replace as needed.
2. Clean and/or replace filters more often or
move unit to cleaner environment.
3. Eliminate extension cord.
4. Reposition unit on a level surface.
1. Reduce air pressure, then check all fittings with a soap
solution for air leaks and tighten as needed.
Do not overtighten.
2. Check if accessory CFM is met by Compressor.
If Compressor doesn't reach accessory
CFM, you need a larger Compressor.
1. Replace belt guard.
2. Reduce air pressure, then check all fittings with a soap
solution for air leaks and tighten as needed.
Do not overtighten.
3. Reposition unit on a level surface.
Install inline air filter/dryer, and/or relocate
to less humid environment.
Pull on test ring of safety valve. If it still pops, replace.
Reduce air pressure, then check all fittings with a soap
solution for air leaks and tighten as needed.
Do not overtighten.
Have tank replaced by a qualified technician.
Drain moisture from tank daily to prevent future corrosion.