Whirlpool 1188927 Use And Care Manual page 4

Table of Contents

Advertisement

Available languages

Available languages

DEHUMIDIFIER U SE
........
(
Starting/Stopping
the Dehumidifier
NOTE: Before turning on the dehumidifier, be sure that the
bucket is empty and fits all the way into the dehumidifier.
Control
Type 1
NOTES:
Minimum operating temperature
is 65°F (18°C) for model
AD25B.
Minimum operating temperature
is 55°F (13°C) for model
AD25D.
A
/
/
/
/
/
Dry
CUD_y
B
/
:0nfinu0usRun
DRYNESSCONTROL
A. Light glows, indicating the bucket is full or is not in correct position.
B. Adjusts amount of moisture removed from room.
Control Type 2
NOTE: Minimum operating temperature is 55°F (13°C).
A
FAN SPEED
i
C
A. Light glows, indicating the bucket is full or is not in correct position.
B. Adjusts amount of moisture removed from room.
C. Selects fan speed.
Electrical
Shock Hazard
Plug into a grounded
3 prong outlet.
Do not remove ground
prong.
Do not use an adapter,
Do not use an extension
cord.
Failure to follow these instructions can result in death,
fire, or electrical
shock.
1.
2.
Plug into a grounded 3 prong outlet.
To turn on dehumidifier, turn DRYNESS CONTROL clockwise.
IMPORTANT:
If the Empty/Adjust
Bucket light comes on, the
dehumidifier
will not operate. Empty or adjust bucket.
3. To turn off dehumidifier, turn DRYNESS CONTROL
counterclockwise
to OFE
Empty/Adjust Bucket Light
If this light is on, the dehumidifier
is not running. This light
indicates that you need to check:
If the bucket is full, empty and reinstall bucket.
If the bucket is not in position, remove the bucket and
reinstall. Make sure the bucket fits all the way into the
dehumidifier
and the light is off, or dehumidifier
will not run.
Fan Speed (Control Type 2 Models
Only)
The Fan Speed controls fan operation
High--for
faster moisture removal
Low--for
quieter moisture removal
Dryness Control
The Dryness Control regulates the amount of moisture in the
room. Turn the control knob clockwise for more drying. Turn the
control knob counterclockwise
for less drying. Turn the control
knob to "Dry" to maintain average humidity conditions.
NOTES:
For the first few days of use, turn the DRYNESS CONTROL
clockwise to CONTINUOUS RUN to remove extra moisture
from the furnishings as well as the room air.
For all models except AD25B, the Deicer will turn off the
compressor if a low temperature condition exists. Turning the
Dryness Control will not increase or decrease the amount of
moisture removed. Compressor
operation will resume when
the low temperature
condition no longer exists.