INSTALLATION REQUIREMENTS
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Specific electrical requirements are listed in the chart below.
Follow the requirements for the type of plug on the power supply
cord.
Power supply cord
Wiring requirements
115 volt (103.5 min. to
126.5 max.)
15-amp time-delay fuse or
circuit breaker
Recommended
grounding
method
This dehumidifier
must be grounded. This dehumidifier
is
equipped with a power supply cord having a grounded 3 prong
plug. To minimize possible shock hazard, the cord must be
plugged into a mating, grounded 3 prong outlet, grounded in
accordance with all local codes and ordinances. If a mating outlet
is not available, it is the customer's
responsibility
to have a
properly grounded 3 prong outlet installed by a qualified electrical
installer.
It is the customer's
responsibility:
To contact a qualified electrical installer.
To assure that the electrical installation is adequate and in
conformance
with National Electrical Code, ANSl/NFPA 70 -
latest edition, and all local codes and ordinances.
Copies of the standards listed may be obtained from:
National Fire Protection Association
One Batterymarch
Park
Quincy, MA 02269
A. Allow at least 12" to 18" (30.5 to 45.7 crn) of air space.
You will need a level surface strong enough to support the
dehumidifier
when its bucket is full of water.
Keep all outside doors, windows and other openings closed
when you are operating dehumidifier. Humid outdoor air will
increase dehumidifier
workload.
Install dehumidifier
in an area where the temperature
will not
fall below: 65°F (18°C) for Control Type I (model AD25B),
55°F (13°C) for Control Type 1 (model AD25D) and Control
Type 2, 38°F (3°C) for Control Types 3 and 4. Lower
temperatures
will cause your performance to drop.
Do not block the louvers on the front panel.