The microwave hood is set for ventless (recirculating)
instaliation. For wali or roof venting changes to the venting
system must be made.
CAUTtON:
To reduce
risk of fire and to
properly
exhaust
air, be sure to vent air
outside.
Do not vent exhaust
air into
spaces
within
walls
or ceilings
or into
attics,
craw_ spaces
or garages.
For wail or roof venting methods:
Choose between roof venting or wall venting.
If the waii exhaust method is chosen, be sure that there is
proper clearance within the wall for the exhaust vent.
Vent materials needed for installation are not included.
We recommend:
,/using waft and roof caps that have back-draft dampers.
,/using rigid metal vent.
,/that length of vent and number of elbows should be kept
to a minimum to provide efficient performance.
,/that size of vent should be uniform.
,/using duct tape to seal aii joints in tile vent system.
,/using cauIking compound to seal exterior wall or roof
opening around cap.
,/two elbows shouId not be instaIled together.
We do not recommend:
,/flexible metal vent.
NOTE:If fiexibie metal vent must be used, calculate each
foot of fiexibie metai vent as two feet of rigid metal vent.
Flexibte metal elbows count twice as much as standard
elbows.
Vertical venting
Salida de aire per el cielo raso
roof cap
caperuza de cielo raso
(8.3x 25.4cm)
through-the-roof
atrav_s delcielorasoperun orificio
de3-1/4" x 10"
(8.3 x 25.4 cm)
Wall venting
Salida de aire per la pared
wa,oap
caperuza de pared
3-1/4" x 10" (8.3 x 25.4 cm)
through-the-wall
a tray,s de la pared per un orificio
de 3-1/4" x 10" (8.3 x 25.4 cm)
Round vent transition
TransiciOn de conducto de salida de aire redondo
6" (15.2 cm) rnin. diameter
round vent
_
wall
cap
conducto de salida de aire
-_ ......
_JJcaperuza
redondo de 6" (15.2 cm) de
_°'_
de pared
di_metro m[nimo
elbow
code
3" (7.6 cm) minimum height
(required for damper to fully open)
Altura minima de 3" (7.6 cm)
(necesaria para que la compuerta
se abra completamente)
\
3-1/4" x 10" to 6"
(8.3 x 25.4 cm to 15.2 cm) round
vent transition
transici6n de conducto de salida de
aire redondo de 3-1/4" x 10"a 6"
(8.3 x 25.4 cm a 15.2 cm)
Salida de aire
La campana del horno ha side disefiada para set instalada
sin saiida de aire (recircuiaciOn). Para salida de aire en la
pared o en eI cieIo raso, @ben hacerse cambios en et
sistema de satida de aire.
PRECAUCI6N:
para reducir
el riesgo
de
incendio
y para instalar
el sistema
de
salida
de aire adecuado,
asegQrese
de
que el aire salga al exterior.
No ponga
la
salida
de aire en espacios
dentro
de
paredes
o cielos
rases
o en _ticos,
s6tanos
de peque_ia
altura
o garajes.
Para m6todos de salida de aire a trav6s de ia pared o el cielo
raso:
Decida entre instalar la salida de aire a tray@ del cielo raso
o de una pared.
Si se decide per et m6todo de salida de aire a trav6s de Ia
pared, asegOresede que hayael espacio adecuado dentro de
la pared para e! conducto de salida de aire.
No se incluyen los materiales det conducto de salida de aire
que se necesitan para la instalaciOn.
Recomendamos:
,/ Usar tapas de pared y techo que tengan regulador de
contracorriente.
,/ usar un conducto de salida de aire met_iico y rigido.
7 que Ia Iongitud del conducto de saiida de aire y ei
nOmerode codes se mantengan a un minimo para Iograr
un rendimiento eficiente.
7 que ias dimensiones dei conducto sean uniformes.
,/ usar cinta para conducto para seiiar todas ias uniones en
ei sistema de saiida de aire.
,/ usar masiiia para caiafatearpara seiiar ia pared exterior o
la abertura en el cieio raso alrededor de la caperuza.
,/ no se @ben instalar dos codes juntos.
No recomendamos:
,/conducto
de salida de aire met_Iico flexible
NOTA:si debe usarse un conducto met_tico flexible, catcub
cada pie de conducto metAibo fiexibie come si fueran dos
pies de conducto met_Iico rigido. Los codes de metal
flexible hacen per dos codes est_ndar.
6
Recommended vent length:
Use 3-1/4" X 10" (8.3 x 25.4 cm) rectangular or 6" (15.7 cm)
round vent.
The total length of the vent system including straight vent,
elbow, transitions, wail or roof caps must not exceed the
equivalent of 140 feet (42.7 m) of 3-I/4" X 10" (8.3 x
25.4 cm) rectangular or 6" (15.7 cm) diameter round vent.
For best performance, use no more than three 90 degree
elbows.
To caicuiate the bngth of system you need, add the
equivalent feet for each vent piece used in the system. See
the following examples:
3-1/4" x 10" (8.3 x 25.4 cm)
vent system:
1 - 3-1/4" x 10"
(8.3 x 25.4 cm)
90 ° elbow
= 25 ft.
(7.6 m)
1-walicap
=40ft.
(12.2m)
8 ft. (2.4 m) straight
= 8 ft.
(2.4 m)
Length of 3-I/4" x 10"
(8.3 x 25.4 cm) system = 73 ft.
(222 m)
6" (15.2 cm) vent system:
I - transition
= 5 ft.
(1.5 m)
2 - 90°eibows
= 20 ft.
(6.1 m)
1-waftcap
=40ft.
(12.2m)
8 ft. (2.4 m) straight
= 8 ft.
(2.4 m)
Length of 6" (152 cm)
system
= 73 ft.
(222 m)
If the existing vent is round, a rectangular-to-round adapter
must be used and a rectangular 3" (7.6 cm) extension vent
between the damper assembly and adapter must be installed
to prevent damper from sticking.
Recommended standard fittings
Accesorios est_ndar recomendados
3d/4" x 10"to 6"= 5 ft.
3.3x 25.4cma
15.7cm= 1.5m)
3-1/4" x 10"a 6"= 5 pies
roof c ap
caperuza decieloraso
3-1/4"x10"= 24ft.
(8.3 x25.4cm = 7.3m)
3-1/4" x 10"= 24 pies
wailcap
caperuza de pared
1OfL
31/4 xlO
4Oft
(3m)
8.3x25Acm=12.2 m
10 pies
3-1/4"x 10"= 40 pies
45 _ elbow
codede 45_
2
5
(1.5 m)
5
pies
90: elbow
3-1/4"x 10"= 25 ft.
(8.3x 25.4cm = 7.6m)
3-1/4"x 10"= 25 pies
flatelbow
codeplane
3d/4"x lO"= lO ft.
&3 x25.4 sm=7.6 m
3-1/4"x 10"= 10 pies
3-1/4" x 10" (8.3 x 25,4 cm) vent system
Sistema de salida de aire de 3-1/4" x 10"
(8.3 x 25.4 cm)
90° elbow
6 ft.
6" (15.2 cm) vent system
Sistema de salida de aire de 6" (15.2 cm)
6 ft.
90° elbows
___
6 pies ___
code de 90°
(1.8 m)
/
2 ft, 2 pies (0,6m)
JL
transition
traneici6n
wall cap
caperuza de
pared
Longitudrecemendada del cenductede salida de aire:
Use un conducto de salida de aire rectangular de 3-1/4" x
10" (8.3 x 25.4 cm) o redondo de 6" (15.2 cm).
La iongitud totat det sistema de saiida de aire, inciuyendo el
conducto de saiida de aire recto, ei code, ias transiciones,
las caperuzas de pared o cielo raso no deben exceder ei
equivaiente a 140 pies (42.7 m) de conducto rectangular de
saiida de aire de 3-1/4" x 10" (8.3 x 25.4 cm) o conducto
redondo de 6" (15.2 cm) de di_metro.
Para mejores resuitados, no use mAs de tres codes de 90°.
Para catcular ia iongitud dei sistema que necesita, agregue
la equivabncia en pies para cada pedazo de conducto usa@
en et sistema. Yea los siguientes ejemplos:
Sistema de salida de aire de
3-1/4" x 10" (8.3 x 25.4 cm):
1 - Code de 90°y
3-1/4" x 10"
(8.3 x 25.4 cm)
= 25 pies
(7.6 m)
I - Caperuzade pared
= 40 pies
(12.2 m)
8 pies (2.4 m) recto
= 8 pies
(2.4 m)
Longitud de un sistema
de 3-1/4" x10" (8.3 x 25A m) = 73pbs
(22.2m)
Sistema de salida de aire de 6" (15.2 cm):
1 - transici6n
=
5 pies
(1.5 cm)
2 - codes de 90 °
= 20 pies
(6.1 cm)
I - caperuza de pared
= 40 pies
(12.2 m)
8 pies (2.4 m) recto
=
8 pies
(2.4 m)
Longitud de un sistema
de 6" (152 cm)
= 73 pies
(222 m)
Si el actual conducto de saiida de aire es re@n@, debe
usarse un adaptador de rectangular a redondo y un
conducto de extensi6n rectangular de 3" (7.6 cm) entre el
conjunto de ia compuerta y se debe instalar et adaptador
pare evitar que la compuerta se atasque.