Venting
The microwave heed is set for ventless (recirculating)
installation. For wall or roof venting changesto the
venting systemmust he made.
CAUTION: To reduce
risk of fire and to
properly
exhaust
air, be sure to vent air
outside.
Do not vent exhaust
air into
spaces within
walls
or ceilings
or into
attics,
crawl spaces or garages.
For wall or roof venting methods:
Choose between roof venting or wall venting.
If the wall exhaust method is chosen, be sure that there is
proper clearance within the wall for the exhaust vent.
Vent materials needed for installationare net included.
Wall and roof caps must have hack-draft damper.
We recommend:
V" using rigid metal vent.
7' that length of vent and number of elbows should be
kept to a minimum to provide efficient performance.
V" that size of vent should be uniform.
V" using duct tape to seal all joints in the vent system.
7' using caulking compound to seal exterior wall or roof
opening around cap.
V" two elbows should not be installed together.
We do NOT recommend:
7 flexible metal vent.
NOTE:If flexible metal vent must be used, calculate each
foot of flexible metal vent as two feet of rigid metal vent.
Flexible metal elbows count twice as much as standard
elbows.
Vertical venting
Dechargeverticale
roof cap
houche de ddcharge surfeit
3-1/4" x 10" through-the-root vent
houche de d_charge 3-1/4 pox 10 po
travers le toit
Wall venting
Decharge_ travers le rnur
wallca,
__
bouche de d_charge morale
Round vent transition
Raccord de transitionrectangnlaire/circulaire
rootcap
bouche de _
decharge sur toit
e" min. diameter roundvent
diamNre minimum de 6 po
elbow
condo
3" minimum height (required for
damper to Mly open)
hauteur minimaie 3 po
(n_cessaire pour la manoeuvre
complete du volet de r_glage)
3-1/4"x 10" to6"round venttransition
raccard de transition
rectangulaire/circulaire -
3-1/4pox 10 po le po de diam_tre
Configuration de
vent|lat=on
L'ensemhleFour _ micro-ondes/Hotte a _t_ configurd
I'usine pour le fonctionnement sans extraction
(recyclage). Pour rextractien avec d_charge _ travers le
tour ou le toit, on doit modifier le syst_me de ddcharge.
MISE EN GARDE
: Pour garantir
une bonne
ventilation
et pour
rninimiser
les risques
d'incendie,
veiller
_ ce que rair extrait
par la
hotte
soir d_charg_
a I'ext_rieur.
Ne pus d_charger
Fair extrait
duns
une cavit_
murale
ou duns un
espace
ferm_ (plafond,
grenier,
garage,
vide sanitaire).
O_charge_ travers le tour ou le toit :
Choisir la methode de decharge de Fair extrait : & travers le
toit ou & travers lemur.
Pour la decharge & travers lemur, prevoir une distance de
s@aration adequateentre les materiaux du mur et le conduit
de decharge.
Los materiaux n_cessairespour la r_alisation du circuit
de d_charge ne sent pus inclus.
La beuche de d_charge (murale ou sur teit) dolt comporter
un clapet anti-reflux.
NOUS recommandens
:
V" circuit de dechargeen conduit metallique rigide.
€" minimiser la Iongueurdu circuit et le hombre de coudes,
pour optimiser I'efficacit&
€" emploi de conduits de taille uniforme.
V" utilisation de ruban adhesif pour conduits pour le
scellement de chaque jointure du circuit.
V" emploi d'un compose de calfeutrage pour 1'etancheit6
entre la bouche de decharge et le mur oule toit.
V" ne pas connecter deux coudes ensemble.
Neus deconseillens :
V" emp]oi de conduit metallique flexible.
NOTE: S'il est necessaired'utiliser du conduit metallique
flexible, considerer que la Iongueur 6quivalente de chaque
section de conduit flexible est le double de sa Iongueur
physique (1 pi de conduit flexible = 2 pi de conduit rigide; 1
coude de metal flexible = 2 coudes standard de metal
rigide).
6
Recommended vent length:
Use 3-1/4" X 10" rectangular or 6" round vent.
The total lengthof the vent system including straight vent,
elbow, transitions, wall or roof caps must not exceed the
equivalent of 140 feet of 3-1/4" X 10" rectangular or 6"
diameter round vent.
For best performance, use no more than three 90 degree
elbows.
To calculate the length of system you need, add the
equivalent feet for each vent piece used in the system. See
the following examples:
3-1/4" x 10" vent system:
1 - 3-1/4" x 10"
90 ° elbow
= 25 ft.
1 - wall cap
= 40 ft.
8 feet straight
= 8 ft.
Length of
3-1/4" x 10"system
= 73 ft.
6" vent system:
1 - transition
= 5 ft.
2 - 90° elbows
= 20 ft.
1 - wall cap
= 40 ft.
8 feet straight
= 8 ft.
Length of 6" system
= 73 ft.
If the existing vent is round, a rectangular-to-round adapter
must be used and a rectangular 3" extension vent between
the damper assembly and adapter must be installed to
prevent damper from sticking.
Recommended standard fittings
Raccords standard recorrnrnandes
3-1/4" x i0" to 6" = 5 ft.
I
,,
i transltlOll
3-1/4 pc x 10 pc/ 6 pc
dedam.=5p
31/4 xl0 roofcap 24ft
bouche de d_cbarge sur toit
3-1/4 pcx 10 pc = 24 pi
3-1/4"x 10"
90° elbow = 25 ft.
3-1/4 pc x 10 pc
coude 90° = 25 pi
90° elbow = 10 ft.
coude 90° = 10 p_
3-1/4"x 10"
wall cap = 40 ft.
bouche de
d_cbarge murale
3-1/4 pc x 10pc =
40 pi
45 ° elbow = 5 ft.
coude 45° = 5 pi
3-1/4" x 10"
flat elbow = 10 ft.
coude plat
3-1/4 pc x 10 pc =
lOpi
3-1/4" x 10" vent system
Circuit en conduitrectangnlaire de 3-1/4 pc x 10 pc
3-1/4"x 10"
gO°elbow_.
Coudego °
\f-
3-1/4pox le po
6 ft,
6pi
I
7
2 ft. 12pi)
_L_
-_'_l
wall cap
rFbouche
de
decharge
murale
6" vent system
Circuit en conduitcirculairede 6 pc de diarnetre
90° elbows
6 ft. /
coudes90°
-_----
e pi
=t.
transition
raccard detransition
Lengueurdu circuit de d_charge - Recommandations :
Utiliser du conduit rectangulaire de 3-1/4 pc x 10 pc, ou du
conduit circulaire de 6 pc de diam_tre.
La Iongueur totale du circuit de d_charge- incluant sections
rectilignes, coudes, raccords de transition, et bouche de
d_charge- ne dolt pas d@asser I'_quivalent de 140 pi de
conduit rectangulaire de 3-1/4 pc x 10 pc, ou de 6 pc de
diam_tre.
Pour optimiser la performance, ne pas incorporer plus de 3
coudes _ 90 degres.
Pour calculer la Iongueur du circuit, d_terminer la Iongueur
_quivalente de chaque composant du circuit, et calculer le
total de ces valeurs. Voir les exemples suivants :
Circuiten conduitrectangnlaire
de 3-1/4 po x 10 pc
1 - coude 90°
3-1/4 pc X 10 pc
=
25 pi
1 - bouche de d_charge murale
=
40 pi
section droite de 8 pi
=
8 pi
Longueur _quivalente de conduit
3-1/4 pc X 10 pc
=
73 pi
Circuit en conduitcirculaire
de 6 pc de diarn_tre
1 - raccord de transition
=
5 pi
2 - coudes 90°
=
20 pi
1 - bouche de decharge murale
=
40 pi
section droite de 8 pi
=
8 pi
Longueur _quivalente de conduit
de 6 pc de diametre
73 pi
S'il y a d_j& un conduit d'_vacuation & section circulaire, on
dolt utiliser un raccord de transition rectangulaire/circulaire,
et une extension de 3 pi & section rectangulaire entre le volet
de r_glage et le raccord de transition, pour empecher un
blocage du volet de r_glage.

Advertisement

loading