Electrical Connection; Integrated Socket; Exhaust Air Connection - Bosch V20-UL Operating, Care And Installation Instructions Manual

Table of Contents

Advertisement

Electrical
connection
Connect
to individual
Brunch
Circuit.
Do not use an adapter.
Do not use an extension
cord.
Do not remove ground prong.
Your dryer comes with a power
supply cord:
-
ULlisted
in the USA,
-
CSA listed in Canada.
When installing the receptacle
for
the dryer cord, ensure that the
power supply cord is accessible
when the dryer is in the installed
position.
The power cord should only be
replaced by a qualified person.
Use a 4-wire power supply cord.
Grounding
instruction
The dryer comes with a cord which
has an equipment
grounding
conductor
and a grounding
plug.
The plug must be plugged into an
appropriate
outlet which has been
properly installed and grounded
in
accordance
with all local
regulations
and ordinances.
Improper connection
of the
equipment
grounding
conductor
may result in electric shock.
Have the appliance
checked
by
a qualified electrician
or service
technician
if you are in doubt as
to whether the dryer has been
properly grounded.
Integrated
socket
This appliance
is equipped
with a
socket for connecting
a washer
without fuses. Only the listed
washer may be connected.
For all
other connections
Bosch will
assume
no liability.
Use copper
conductors
only.
Connect to a 30 A minimum
individual branch circuit, fused at
30 A maximum.
Use receptable
only for:
208 - 240 VAC 60 Hz 11 A
washer: WFR2460UC,
WFL2060UC.
Exhaust
air connection
You can use the exhaust air set
which can be obtained from
customer
service or your local
dealer (WTZl 130).
Also any products
which are
commercially
available can be used
for the exhaust air duct:
-
flexible tubes,
-
galvanised
sheet metal ducts or
tubes,
-
connection,
transfer and
by-pass
adapters for use in flat
duct or tubular ducting
systems,
-
wall boxes for ventilation
into
the open air or into an air shaft,
-
adapters for rectangular
ducts,
-
rectangular
ducts or plastic
tubesone-way
flap.
1. To reduce the risk of fire, this
dryer MUST BE EXHAUSTED
OUTDOORS.
2. To reduce the risk of fire, do
not use the ductwork
longer
than recommended.
3. DO NOT use a plastic or
non-metal
duct with this dryer.
4. DO NOT use a duct smaller
than 4 inches in diameter.
5. DO NOT use exhaust hoods
with magnetic
latches.
6. DO NOT exhaust the dryer into
a chimney, furnace cold air
duct, attic, crawl space, or any
other ductwork
used for
venting.
7. DO NOT install a flexible duct
in an enclosed
wall, ceiling or
floor.
8. DO NOT crush or kink the
duct.
9. Do clean and inspect the
exhaust system on a regular
basis; at least once a year.
10. The exhaust duct must
terminate
in a manner to
prevent back drafts or entry of
birds or other wildlife.
The Bosch dryers are intended to
be vented outdoors.
To prevent
build-up
of moisture and
accumulation
of lint indoors, as well
as to maintain maximum
drying
efficiency,
it is recommended
that
the dryer is vented outdoors.
[-_
Position the exhaust air duct so
that there is no counter-
pressure (e.g. from wind) on the
exhaust outlet.
All materials must be
heat-resistant
up to 80 °C and
humidity-resistant.