Selecting The Echo Sounder Output Power - Furuno GP-1850DF Installation Manual

Color dgps/plotter/sounder; color gps/plotter/sounder
Hide thumbs Also See for GP-1850DF:
Table of Contents

Advertisement

3.8 Selecting the Echo Sounder Output Power

The echo sounder output power can be selected for 600 W (for transducer 520-
5PSD, 520-5PWD, 520-5MSD) or 1 kW (50/200-1T), and the default setting is 600
W.
Note: Matching Box MB-1000 and cable assembly 02S4092 are required for 1kW
transducer connection. For details, see the interconnection diagram at the end of
this manual.
Attach the TX power label (supplied) to the place shown below, and draw a line
through the power which you don't use by oil base magic marker.
To change to 1 kW power, do the following:
1. Turn off the power. Wait at least one minute before opening the cover, to allow
capacitors to discharge.
2. Remove nuts attached to XDR, SPD/TEMP. DGPS, NMEA and power supply
connectors at the rear of the display.
3. Remove nut and washer attached to the ANT connector.
4. Remove ten binding screws (M3 x 10) from the rear of the display unit to sepa-
rate the panel/chassis assembly from the cover assembly.
Attach TX POWER
Label to here.
Warning Label
Figure 3-14 Display unit, top view
3-10