Viking VMOS200 Service Manual page 22

Hide thumbs Also See for VMOS200:
Table of Contents

Advertisement

CDMOS200
DMOS200
VMOS200
CVMOS200
PROCEDURE
LETTER
M
FOIL PATTERN ON THE PRINTED WIRING BOARD TEST
To protect the electronic circuits, this model is provided with a fine foil pattern added
1. Foil pattern check and repairs.
5) Make a visual inspection of the varistor.
6) Reconnect all leads removed from components during testing.
7) Re-install the outer case (cabinet).
8) Reconnect the power supply cord after the outer case is installed.
9) Run the oven and check all functions.
2. Follow the troubleshooting guide given below, if indicator does not light up after above check and repairs
are finished.
1) Disconnect the power supply cord, and then remove outer case.
2) Open the door and block it open.
3) Discharge high voltage capacitor.
4) Disconnect the leads to the primary of the power transformer.
5) Ensure that these leads remain isolated from other components and oven chassis by using
6) After that procedure, re-connect the power supply cord.
7) Follow the troubleshooting guide given below for repair.
8) Disconnect the power supply cord, and then remove outer case.
9) Open the door and block it open.
10) Discharge high voltage capacitor.
11) Reconnect all leads removed from components during testing.
12) Re-install the outer case (cabinet).
13) Reconnect the power supply cord after the outer case is installed.
14) Run the oven and check all functions.
TEST PROCEDURES
to the primary on the PWB, this foil pattern acts as a fuse.
1) Disconnect the power supply cord, and then remove outer case.
2) Open the door and block it open.
3) Discharge high voltage capacitor.
4) Follow the troubleshooting guide given below for repair.
STEPS
OCCURRENCE
1
Only pattern at "a" is broken.
2
Pattern at "a" and "b" are broken.
Check for burned damage and
examine the transformer with a tester
for the presence of layer short-circuit
(check the primary coil resistance which
is approximately 210 ohm ± 15%). If any
abnormal condition is detected, replace
the defective parts.
insulation tape.
STEPS
OCCURRENCE
The rated AC voltage is not present between
1
Pin No. 1 of the 2-pin connector (A) and the
common terminal of the relay RY1.
The rated AC voltage is present at primary
2
side of low voltage transformer.
COMPONENT TEST
CAUSE OR CORRECTION
*Insert jumper wire J1 and solder.
*Insert the coil RCILF2003YAZZ between "c" and "d".
d
a
CAUSE OR CORRECTION
Check supply voltage and oven power cord.
Low voltage transformer or secondary circuit defective.
Check and repair.
20
CN - A
(J1)
b
c

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dmos200Cvmos200Cdmos200

Table of Contents