6. REFRIGERANT FLOW DIAGRAM

Indoor Unit: XS1852
Insulation of Refrigerant Tubing
IMPORTANT
To prevent heat loss and wet floors due to dripping
of condensation, both the wide and narrow tubes
must be well insulated with a proper insulation
material. The thickness of the insulation should be
a min. 5/16 in.
CAUTION
Indoor Unit
Wide tube
O. D.
5/8"
(15.88 mm)
Narrow tube
O. D.
1/4"
(6.35 mm)
After a tube has been
insulated, never try to bend it
into a narrow curve because it
can casue the tube to break or
crack.
Outdoor Unit: C1852, CL1852
Outdoor Unit
Wide tube
service valve
Accumulator
Narrow tube
Capillary
service valve
tube
Thickness:
Min. 5/16 in.
– 16 –
Insulation
Wide tube
Thickness:
Min. 5/16 in.
Narrow tube
0999_C_I
SM830079