Honeywell THX9000 Prestige HD Installation Manual page 5

Hide thumbs Also See for THX9000 Prestige HD:
Table of Contents

Advertisement

Available languages

Available languages

System-specific wiring guides
Conventional systems
1H/1C System (1 transformer)
C
24VAC common
R
Power [1]
Rc
[R+Rc joined by jumper]
W
Heat relay
Y
Compressor contactor
G
Fan relay
**
Heat Only System [3]
C
24VAC common
R
Power [1]
Rc
[R+Rc joined by jumper]
W
Heat relay
Heat Only System With Fan [4]
C
24VAC common
R
Power [1]
Rc
[R+Rc joined by jumper]
W
Heat relay
G
Fan relay
Cool Only System [5]
C
24VAC common
R
Power [1]
Rc
[R+Rc joined by jumper]
Y
Compressor contactor
G
Fan relay
**
**
[See note on page 4]
[1] Power supply. Provide disconnect means and overload protection as required.
[2] Remove jumper (R to Rc) for systems with two transformers. Common connection
must come from cooling transformer.
[3] In Installer Setup, set system type to Heat Only, No Fan.
[4] In Installer Setup, set system type to Conventional with zero cooling stages.
[5] In Installer Setup, set system type to Conventional with zero heat stages.
[6] In Installer Setup, set system type to Conventional with 2 heat AND 2 cool stages.
[7] In Installer Setup, set changeover valve to O or B.
[8] In Installer Setup, set to Heat Pump with 1 compressor stage and no auxiliary heat stages.
[9] In Installer Setup, set to Heat Pump with 1 compressor stage and 1 auxiliary heat stage.
[10] In Installer Setup, set to Heat Pump with 2 compressor stages and no auxiliary heat stages.
[11] In Installer Setup, set to Heat Pump with 2 compressor stages and 1 auxiliary heat stage.
[12] "L" terminal sends a continuous output when thermostat is set to Em. Heat, and acts
as a system monitor when in Heat, Cool or Off modes.
Français : voir la page 17 • Español: vea la página 33
**
**
5
1H/1C System (2 transformers)
C
24VAC common
R
Power (heating) [1]
Rc
Power (cooling)
W
Heat relay
Y
Compressor contactor
G
Fan relay
**
2H/2C System (1 transformer) [6]
C
24VAC common
R
Power [1]
Rc
[R+Rc joined by jumper]
W
Heat relay (stage 1)
W2
Heat relay (stage 2)
Y
Compressor contactor (stage 1)
Y2
Compressor contactor (stage 2)
G
Fan relay
**
2H/2C System (2 transformers) [6]
C
24VAC common
R
Power (heating) [1]
Rc
Power (cooling)
W
Heat relay (stage 1)
W2
Heat relay (stage 2)
Y
Compressor contactor (stage 1)
Y2
Compressor contactor (stage 2)
G
Fan relay
**
See [notes] below.
[1,
2]
**
**
[1,
2]
**