Honeywell TB7100A1000 MultiPRO Product Data page 7

Multispeed and multipurpose thermostat for conventional, heat pump, fan coil and ptac systems
Hide thumbs Also See for TB7100A1000 MultiPRO:
Table of Contents

Advertisement

1
C
L1
(HOT)
G
Y
L2
24 VAC
O/B
RC
R
HEAT RELAY
1
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD
PROTECTION AS REQUIRED.
2
FACTORY INSTALLED JUMPER.
3
WHEN USING BATTERIES, THE 24V COMMON CONNECTION IS
OPTIONAL.
Fig. 13. Typical hookup of heat-only system.
1
C
L1
G
(HOT)
Y
24 VAC
O/B
RC
L2
R
HEAT RELAY
FAN RELAY
1
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD
PROTECTION AS REQUIRED.
2
FACTORY INSTALLED JUMPER.
3
WHEN USING BATTERIES, THE 24V COMMON CONNECTION
IS OPTIONAL.
Fig. 14. Typical hookup of heat-only system with fan.
1
C
L1
G
(HOT)
Y
24 VAC
O/B
L2
RC
2
R
COMPRESSOR CONTACTOR
FAN RELAY
1
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD
PROTECTION AS REQUIRED.
2
FACTORY INSTALLED JUMPER.
3
WHEN USING BATTERIES, THE 24V COMMON CONNECTION
IS OPTIONAL.
Fig. 15. Typical hookup of cool-only system.
TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT
3
W1
G2
G3
S1
S2
2
INDOOR TEMPERATURE
SENSOR/REMOTE
SETBACK
M27418
3
W1
G2
G3
S1
S2
2
INDOOR TEMPERATURE
SENSOR/REMOTE
SETBACK
M27419
3
W1
G2
G3
S1
S2
INDOOR TEMPERATURE
SENSOR/REMOTE
SETBACK
M27420
Heat Pump System Wiring
L1
(HOT)
24 VAC
L2
1
CHANGEOVER VALVE
COMPRESSOR CONTACTOR
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD
1
PROTECTION AS REQUIRED.
2
FACTORY INSTALLED JUMPER.
3
WHEN USING BATTERIES, THE 24V COMMON CONNECTION IS
OPTIONAL.
4
"O/B" TERMINAL SET TO CONTROL AS EITHER "O" OR "B" IN THE
INSTALLER SETUP.
5
OPTIONAL INDOOR REMOTE SENSOR OR REMOTE SETBACK.
WIRES MUST HAVE A CABLE SEPARATE FROM THE THERMOSTAT
CABLE.
Fig. 16. Typical hookup of single-stage heat pump with no
auxiliary heat (1H/1C).
L1
(HOT)
24 VAC
L2
1
4
CHANGEOVER VALVE
COMPRESSOR CONTACTOR
FAN RELAY
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD
1
PROTECTION AS REQUIRED.
2
FACTORY INSTALLED JUMPER.
3
WHEN USING BATTERIES, THE 24V COMMON CONNECTION
IS OPTIONAL.
4
"O/B" TERMINAL SET TO CONTROL AS EITHER "O" OR "B"
IN THE INSTALLER SETUP.
5
OPTIONAL INDOOR REMOTE SENSOR OR REMOTE SETBACK.
WIRES MUST HAVE A CABLE SEPARATE FROM THE THERMOSTAT
CABLE.
Fig. 17. Typical hookup of single-stage heat pump with
auxiliary heat (2H/1C).
7
3
C
G
Y
O/B
4
RC
2
R
INDOOR TEMPERATURE
SENSOR/REMOTE
FAN RELAY
3
C
G
Y
O/B
RC
2
R
INDOOR TEMPERATURE
SENSOR/REMOTE
SETBACK
AUXILIARY HEAT RELAY
W1
G2
G3
S1
S2
5
SETBACK
M27421
W1
G2
G3
S1
S2
5
M27422
63-2675—03