Table 5-2. Advanced Diagnostics Error Codes
Error
Code
Description
Memory Test
210-xx
Incrementing pattern test.
210-01
Data read from block did not match
data written.
210-02
Scan of test block prior to testing.
210-05
Inverted pattern compare, but RAM
was correct.
210-10
Mapping LIM block, LIM page
not present.
211-xx
Random pattern test.
211-01
Test failed.
211-02
Error while saving test block.
211-03
Error while restoring test block.
211-04
Insufficient memory to perform test.
211-05
Inverted pattern compare, but RAM
was correct.
Keyboard Test
301-01
Keyboard short test, 8042 self
test failed.
301-02
Keyboard short test, interface
test failed.
301-03
Keyboard short test, echo test failed.
301-04
Keyboard short test.
302-01
Keyboard long test failed.
Addendum 108431-001 (11-88) to
Manual No. 108033-003
Continued
Recommended
Action
Replace the memory board and retest for 210 and 211
error codes.
The following steps apply to error codes 301-xx
through 304-xx:
1. Check the keyboard connection. If disconnected, turn
off the computer and connect the keyboard.
2. Replace the keyboard and retest.
3. Replace the system board and retest.