Electrical Connection
Connect the flexible armored cable that extends from
the surface unit to the junction box using a suitable
strain relief at the point the armored cable enters the
junction box. Then make the electrical connection as
follows.
Electrical
ground
is required
on this appliance.
This appliance
is equipped
with a
copper conductor
flexible
cable. If connection
is
made to aluminum
house wiring,
use only special
connectors
which are approved
for joining
cooper
and aluminum
wires in accordance
with
the
National
Electrical
Code and local codes and
ordinances.
Improper
connection
of aluminum
house wiring
to copper leads can result in a short
circuit or fire. Follow
the connector
manufacturer
recommended
procedure closely.
This appliance is manufactured with a frame connected
green (or bare copper) ground wire.
DO NOT ground
to a gas supply
pipe.
DO NOT connect to electrical
power
supply until
appliance
is permanently
grounded.
Connect the
ground
wire before turning
on the power.
If your cooktop
has a 4-wire
cable to be connected
to a 3-wire
grounded
junction
box (see figure
5):
1. Disconnect the power supply.
2. In the circuit breaker, fuse box or junction box:
connect appliance and power supply cable wires as
shown in figure 5.
Cable from Power Supply
White Wire
(Neutral) d
_-_------z/_,B)
acK
.._
wires -
v]/Reld
Red
:'::
B °x
Wire
Ground Wire J
ted C_I_
al)
(Bare or Green Wire)
Connector (or CSA listed)
Cable from appliance
Figure 5
3=WIRE GROUNDED JUNCTION BOX
36" Models with Warmer
Zone
Where local codes permit
connecting
the appliance-
grounding
conductor
to the neutral
(white)
wire:
If your cooktop
has a 3-wire cable to be connected
to a 3-wire
grounded
junction
box (see figure
4):
1. Disconnect the power supply.
2. In the circuit breaker, fuse box or junction box:
connect appliance and power supply cable wires as
shown in figure 4.
Cable from Power Supply
White Wire
(Neutral)
Red
Wires
Black
Wires
Box
Ground Wire
U.L.-Listed Conduit
Connector (or CSA
(Bare or Green Wire)
listed)
Cable from appliance
Figure 4
3-WIRE GROUNDED JUNCTION BOX
You may not ground
the cooktop
through
the neutral
(white)
wire if cooktop is used
in a new branch circuit
installation
(1996 NEC),
mobile
home, recreational
vehicle,
or where
local
codes do not permit grounding
through
the
neutral
(white)
wire. When grounding
through
the
neutral
(white)
wire
is prohibited,
you must use a
4-wire
power
supply
cable, See Figure 6 & 7.
Failure to heed this warning
may result in
electrocution
or other serious personal
injury.