iNSTALLATiON
AND SERVICE MUST BE PERFORMED BY A QUALiFiED
iNSTALLER.
iMPORTANT:
SAVE FOR LOCAL ELECTRICAL iNSPECTOR'S USE.
READ AND SAVE THESE iNSTRUCTiONS
FOR FUTURE REFERENCE.
FOR YOUR SAFETY: Do not store or use gasoline or other flammable
vapors and liquids in
the vicinity
of this or any other appliance.
Cooktop Dimensions
IMPORTANT INSTALLATION-INFORMATION
All electric cooktops run off a single phase, three-wire
or four-wire cable, 240/208 volt, 60 hertz, AC only
electrical supply with ground.
Please note minimum distances between cooktop and
adjacent and overhead cabinetry is 30" (76.2 cm).
* 30" (76.2 cm) min. for unprotected cabinet
24" (61 cm) min. for protected surface
Cooktop Cutout Dimensions
C
4" X 8" (1 0.2 cm x 20.3 cm)
_____--- opening at the right rear
to route armored cable
if a panel is present
Figure I - 30" Model shown only
30" Ceramic M odel
36" Ceramic M odel
303A(78.1)
21Y2(54.6)
5 (12.7)
29 (73.7)
19Y2 (49.5)
36Y2(92.7)
21Y2(54.6)
5 (12.7)
34s/s (87.9)
19Y2 (495)
30" CeramicModel
293A (75.6)
3078(76.5)
20318 ( 51.7)
203A (52.7)
6 (15.2)
36" CeramicModel
35Y2 (90.2)
357/8 (911)
203/8 (51.7)
203A (527)
6 (152)
All dimensions are in inches (cm).
**Allow
2" (5 cm) space below cooktop to clear the electric cable and allow for
installation of the junction box on the wall at the back of the cooktop.
Printedin United States
P/N 318205400
(0807)
Rev. A
English - pages 1-6
Espahol-
pages 7-12

Advertisement

loading

Summary of Contents for Kenmore 318205430

  • Page 1 iNSTALLATiON AND SERVICE MUST BE PERFORMED BY A QUALiFiED iNSTALLER. iMPORTANT: SAVE FOR LOCAL ELECTRICAL iNSPECTOR'S USE. READ AND SAVE THESE iNSTRUCTiONS FOR FUTURE REFERENCE. FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Page 2 Overhead Cabinet Should Not Exceed m Depth of 13" (33 cm) Min. 30" (76.2 cm) Min. Clearance Between the R_sCt° mcm _ndt e de e n Top of the Cooking Platform and the Bottom Rear Edge of Cutout and Nearest 10"...
  • Page 3: Important Instruction

    important Notes to the Installer An extension cord must not be used Read all instructions contained in these installation with this appliance. Such use may result in a fire, instructions before installing the cooktop. electrical shock, or other personal injury. Remove all packing material before connecting the electrical supply to the cooktop.
  • Page 4 Electrical Connection If your cooktop has a 4-wire cable to be connected Connect the flexible armored cable that extends from to a 3-wire grounded junction box (see figure 1. Disconnect the power supply. the surface unit to the junction box using a suitable 2.
  • Page 5 If cooktop is used in a new branch circuit If your cooktop has a 4 wire cable (see figure installation (1996 NEC), mobile home, recreational 1. Disconnect the power supply. vehicle, or where local codes DO NOT permit 2. Separate the green (or bare copper) and white grounding through the neutral...
  • Page 6 Cooktop Installation 1. Visually inspect t hecooktop for damage. Alsomake sureallcooktop screws aretight (seeFigure 8). 6 Nylon Position brackets on unit cutout 2 Retainer center line brackets Figure 10 Checking Operation Screws Refer to the Use and Care Guide for operation Figure8 not touch cooktop glass or elements.
  • Page 7: Informacionimportante Parala Instalacion

    LA INSTALACION Y EL SERVICIO DEBEN SER EFECTUADOS POR UN INSTALADOR CALIFICADO. IMPORTANTE: GUARDE ESTAS INSTRUCCIONES PARA USO DEL iNSPECTOR LOCAL DE ELECTRICIDAD. LEA Y GUARDE ESTAS INSTRUCCIONES PARA REFERENCIA FUTURA. PARA SU SEGURIDAD: No almanece ni utilice gasolina u otros vapores y liquidos inflamables la proximidad de este o de cualquier otro artefacto.
  • Page 8 El armario superior no debe sobrepasar una profundidad maxima de 13" (33 cm) A.,n 30" (76.2 cm) min. de espacio entre la parte k min. distancia superior del fog6n y la parte inferior de un recomendada entre el armario de madera o borde trasero del corte y el metal sin protecciOn.
  • Page 9: Instrucciones Importantes De Seguridad

    NOTA: El tamaho de los cables y de las conexiones debe Notas irnportantes para el instalador Lea todas las instrucciones contenidas en este manual de estar en conformidad con el tamaho del fusible y con la antes de instalar la estufa. capacidad del electrodomestico y de acuerdo con el C6digo El_ctrico Nacional ANSI/NFPANo.
  • Page 10 Si su cocina tiene un cable de 4 hilos que debe Conexion Electrica conectarse a una caja de juntas con conexion a tierra Conecte el cable blindado flexible que se extiende desde la de 3 hilos (ver figura superficie del artefacto hasta la caja de empalmes Desconecte el suministro el_ctrico.
  • Page 11 Si la cocina se usa en una instalacion nueva de ramal Si su cocina tiene un cable de 4 hilos (ver figura de circuito (1996 NEC), en una casa rodante, en un Desconecte el suministro el_ctrico. vehiculo para recreacion o si los codigos locales NO Separe el alambre verde (o cobre desnudo) y el permiten hacer la conexion...
  • Page 12 Instalad6n de ia estufa 1.Visualmente inspecciones la estufa para dahos. Verifique ademas que todos los tornillos de la estufa est_n bien ajustados (Figura 8). 6 espaciadores. de nilOn Figura 10 Revisi6n de operad6n Consulte el Manual del Usuario para las instrucciones Tornillos de funcionamiento.