Table Of Zones; Directed Electronics, Inc. All Rights Reserved - Directed Electronics Viper 350HV Installation Manual

Hide thumbs Also See for Viper 350HV:
Table of Contents

Advertisement

System Status Chirps
Action
Number of Chirps
Arm
1
Arm
1 (3 second delay), 1
Disarm
2
Disarm
4
Disarm
5

Table of Zones

Zone No.
Trigger type
1
Instant
2
On-board shock sensor
3
Two-stage, progresses from
4
Multiplexed Input
5
Two-stage (similar to doors)
NOTE: The Warn Away® response does not report on the LED.
Long Term Event History
The system stores the last two full triggers in memory. These are not erasable. Each time the unit
sees a full trigger, the older of the two triggers in memory will be replaced by the new trigger. To
access long term event history:
2005
©

Directed Electronics, Inc. all rights reserved

Description
System armed
System armed with Bypass Notification
System disarmed
System disarmed with Tamper Alert
System disarmed NPC® active
Input description
H1/6 BLUE - Connect to optional hood/trunk pins.
Heavy impact detected by the on-board shock
sensor.
Door switch circuit. H1/5 GREEN or H1/7
VIOLET warning to full alarm
BLUE and GREEN wires of optional sensor
plug. Inputs shorter than 0.8 seconds will trigger
a Warn Away response, while inputs longer than
0.8 seconds will instantly trigger a full alarm
sequence and report Zone 4.
Ignition input. H1/9 YELLOW.