STEP 5. Connect
neutral grounding
wire
and the neutral wire (white or center) of
direct wire cable under the center screw
of terminal block.
Center silver-colored
terminal block screw
Externalground
connector
White neutral wire
Bare copper wire
4-Wire
Connection
with Direct Wire
Neutral
grounding wire
(green/yellow)
Strain relief
STEP 6. Place the hook-shaped
end of
the wire over the terminal
block screw.
The open side of the hook should face
to the right. Squeeze
hook end of wire
together to form a loop.
STEP 7. Connect the other two wires
to outer terminal block screws. Use
the same method described
in STEP 6.
STEP 8. Connect
the direct wire cable
(bare) grounding
wire to the external-
grounding
conductor
screw. Tighten all
terminal
blo,_k screws firmly.
STEP 9. Tighten the strain relief screws.
STEP 10. Irsert tab of terminal block
cover into stot of the dryer rear panel.
Secure cow._r with hold-down
screw.
Continue