Water Temperature Adjustment; Operating M Odes Andsettings - Kenmore 153.337021 Use & Care Manual

40 & 50 gallon tall
Hide thumbs Also See for 153.337021:
Table of Contents

Advertisement

160°F (Approx_,,_
Status Light
t_
L, ,\_,_A4,
120°F
_./xO
Position
LOW
Gas Control/Temperature Knob
11
"
VAC
110°F(Approx.)S
70°F(Approx.)_
TEMPERATURES
SHOWN
ARE
APPROXIMATES
AND
MAY VARY.
110
116
116
122
131
140
149
154
(normal shower temp.)
(pain threshold)
35 minutes
1 minute
5 seconds
2 seconds
1 second
instantaneous
45 minutes
5 minutes
25 seconds
5 seconds
2 seconds
1 second
(U.S. GovernmentMemorandum, C.RS.C.,Peter L Armstrong, Sept. 15,1978)
FIGURE 29.
NOTE:
During tow demand
periods when hot water is not
being
used, a lower thermostat
setting
wilt reduce
energy
losses and may satisfy your normal hot water needs. If hot
water
use is expected
to be more than normal,
a higher
thermostat
setting
may be required
to meet the increased
demand.
When
leaving
your
home for
extended
periods
(vacations,
etc.)
turn the
temperature
dial
to its lowest
setting. This wilt maintain the water at tow temperatures
with
minimum
energy losses and prevent the tank from freezing
during cold weather.
Water Temperature
Adjustment
The water temperature setting can be adjusted from 70°F to
160°F. Turn the Gas Control/Temperature
Knob to the desired
setting/temperature.
NOTE: The temperatures
indicated are approximates. The
actual temperature of the heated water may vary.
Status
Light Code
Table 5
LED FLASH SEQUENCE
Short flash once every four second
"Heartbeat", alternates bright/dim
One Flash, three second pause
Two Flash, three second pause
Three Flash, three second pause
Four Flash, three second pause
Five Flash, three second pause
Six-One Flash, three second pause
Six-Two Flash, three second pause
Six-Three Flash, three second pause
Six-Four Flash, three second pause
Seven Flash, three second pause
Eight-One Flash, three second pause
Eight-Two Flash, three second pause
Eight-Three Flash, three second pause
Eight-Four Flash, three second pause
Operating
Modes and Settings
Standard Mode - The controller adjusts the water heater
to maintain the temperature set by the user.
Vacation
Setting
- The Vacation
Setting
(VAC) sets
the controller
at approximately
70°F. This
setting
is
recommended
when the water heater is not in use for a
tong period of time. This effectively
turns the controller
temperature
setting down to a temperature
that prevents
the water in the water
heater from freezing
while
still
conserving energy.
CONTROL STATUS
IDLE (No call for heat, no fault conditions)
Call for Heat (No fault conditions)
Low Flame Signal (control continues to operate)
End Switch Failed Closed
End Switch Failed Open or TCO Limit Lockout
ECO Limit Lockout
Flame Out of Sequence
Soft Lockout* - Retry Limit - Failed TFI (Trial for Ignition)
Soft Lockout* - Recycle Limit - Flame Lost - END Switch Fails
Soft Lockout* - Recycle Limit - Flame Lost
Soft Lockout* - Flame out of Sequence Sensed
Flammable Vapor Sensor (FVS) Lockout
Flammable Vapor Sensor (FVS) Fault Detected
Temperature Sensor Fault Detected
Electronic Fault Detected
Gas Control Valve/Thermostat
Fault Detected
Soft Lockout - 20 minute wait before returning to normal mode.
26