TX
Re-transmission of the procedure signal has been attempted the specified number of times, but failed.
##280
TX
Re-transmission of the procedure signal has been attempted the specified number of times, but failed.
##281
TX
Re-transmission of the procedure signal has been attempted the specified number of times, but failed.
##282
TX
Re-transmission of the procedure signal has been attempted the specified number of times, but failed.
##283
TX
After TCF transmission, DCN has been received.
##284
TX
After EOP transmission, DCN has been received.
##285
TX
After EOM transmission, DCN has been received.
##286
TX
After MPS transmission, DCN has been received.
##287
TX
After EOP transmission, a signal other than PIN, PIP, MCF, RTP, RTN has been received.
##288
TX
After EOM transmission, a signal other than PIN, PIP, MCF, RTP, RTN has been received.
##289
TX
After MPS transmission, a signal other than PIN, PIP, MCF, RTP, RTN has been received.
##290
TX
In V.8 late start, the DIS V.8 ability from the receiving machine was detected, and CI was sent in response; however, the
##670
procedure failed, causing T1 time-over.
RX
In V.8 call reception, the procedure fails to proceed to phase 2 after CM detection, causing T1 time-over.
##671
TX
In V.34 transmission, the procedure fails to proceed from phase 2 to phase 3 or later, causing T1 time-over
##672
RX
In V.34 reception, the procedure fails to proceed from phase 2 to phase 3 or later, causing T1 time-over
##673
TX
In V.34 transmission, the procedure fails to proceed from phase 3 or 4 to the control channel or later, causing T1 time-
##674
over
RX
In V.34 reception, the procedure fails to proceed from phase 3 or 4 to the control channel or further, causing T1 time-over
##675
TX
After transmitting PPS-NULL in ECM transmission, no significant signal has been received, and re-transmission of the
##750
procedure signal has been attempted the number of specified times but failed.
TX
After transmitting PPS-NULL in ECM transmission, DCN has been received.
##752
TX
After transmitting PPS-NULL in ECM transmission, re-transmission of the procedure signal has been attempted the
##753
number of specified times but failed, or T5 time-over (60 sec.) has occurred.
TX
After transmitting PPS-NULL in ECM transmission, re-transmission of the procedure signal has been attempted the
##754
number of specified times but failed.
##755
TX
After transmitting PPS-MPS in ECM transmission, no significant signal has been received, and re-transmission of the
procedure signal has been attempted the number of specified times but failed.
TX
After transmitting PPS-MPS in ECM transmission, DCN has been received.
##757
TX
After transmitting PPS-MPS in ECM transmission, re-transmission of the procedure signal has been attempted the
##758
number of specified times but failed, or T5 time-over (60 sec.) has occurred.
TX
After transmitting PPS-MPS in ECM transmission, re-transmission of the procedure signal has been attempted the
##759
number of specified times but failed.
TX
After transmitting PPS-EOM in ECM transmission, no significant signal has been received, and re-transmission of the
##760
procedure signal has been attempted the number of specified times but failed.
TX
After transmitting PPS-EOM in ECM transmission, DCN has been received.
##762
TX
After transmitting PPS-EOM in ECM transmission, re-transmission of the procedure signal has been attempted the
##763
number of specified times but failed, or T5 time-over (60 sec.) has occurred.
TX
After transmitting PPS-EOM in ECM transmission, re-transmission of the procedure signal has been attempted the
##764
number of specified times but failed.
TX
After transmitting PPS-EOP in ECM transmission, no significant signal has been received, and re-transmission of the
##765
procedure signal has been attempted the number of specified times but failed.
TX
After transmitting PPS-EOP in ECM transmission, DCN has been received.
##767
TX
After transmitting PPS-EOP in ECM transmission, re-transmission of the procedure signal has been attempted the number
##768
of specified times but failed, or T5 time-over (60 sec.) has occurred.
TX
After transmitting PPS-EOP in ECM transmission, re-transmission of the procedure signal has been attempted the number
##769
of specified times but failed.
TX
After transmitting EOR-NULL in ECM transmission, no significant signal has been received, and re-transmission of the
##770
procedure signal has been attempted the number of specified times but failed.
TX
After transmitting EOR-NULL in ECM transmission, DCN has been received.
##772
TX
After transmitting EOR-NULL in ECM transmission, re-transmission of the procedure signal has been attempted the
##773
number of specified times but failed, or T5 time-over (60 sec.) has occurred.
TX
After transmitting EOR-NULL in ECM transmission, ERR has been received.
##774
TX
After transmitting EOR-MPS in ECM transmission, no significant signal has been received, and re-transmission of the
##775
procedure signal has been attempted the number of specified times but failed.
TX
After transmitting EOR-MPS in ECM transmission, DCN has been received.
##777
TX
After transmitting EOR-MPS in ECM transmission, re-transmission of the procedure signal has been attempted the
##778