Installation clearances:
The location must be large enough to allow the dryer door to
open fully.
Dryer Dimensions
*Most installations require a minimum 5½" (140 mm) clearance
behind the dryer for the exhaust vent with elbow. See "Venting
Requirements."
Installation spacing for recessed area or closet installation
The dimensions shown following are for the minimum spacing allowed.
Additional spacing should be considered for ease of installation and servicing.
Additional clearances might be required for wall, door, and floor moldings.
Additional spacing of 1" (25 mm) on all sides of the dryer
is recommended to reduce noise transfer.
For closet installation, with a door, minimum ventilation openings in the top and
bottom of the door are required. Louvered doors with equivalent ventilation
opening are acceptable.
Companion appliance spacing should also be considered.

Electric Dryer

PRODUCT MODEL NUMBERS
NED4600Y, NED4700Y
Minimum spacing for recessed area or closet installation
Minimum Required Spacing
18"*
(457 mm)
29"
1"
1"
(25 mm)
(737 mm)
(25 mm)
A
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
*Additional spacing recommended
14" max.*
48 in.
2
*
(356 mm)
2
(310 cm )
*
24 in.
2
2
(155 cm )
1"*
27
¾"
(25 mm)
(705 mm)
B
3"*
(76 mm)
3"*
(76 mm)
C
W10514172A
08/2013

Advertisement

loading
Need help?

Need help?

Do you have a question about the NED4600Y and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Amana NED4600Y

  • Page 1: Electric Dryer

    Electric Dryer PRODUCT MODEL NUMBERS NED4600Y, NED4700Y Installation clearances: Minimum spacing for recessed area or closet installation The location must be large enough to allow the dryer door to open fully. Minimum Required Spacing Dryer Dimensions 3"* (76 mm) 14" max.* 48 in.
  • Page 2: Electrical Requirements

    ELECTRICAL REQUIREMENTS To supply the required 3 or 4 wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended.

This manual is also suitable for:

Ned4700y