Understanding the PowerVault 35F Configuration: Dell PowerVault 35F User's Guide
Bus:Target:LUN
0:0:0
0:1:0
0:2:0
0:3:0
0:4:0
0:4:1
0:4:2
0:4:3
The Index Table is edited to represent the desired mapping, and saved to FLASH memory.
In addition to configuring the address mapping, SCSI-to-Fibre Channel mode requires that a SCSI interface on the
PowerVault 35F be configured to respond to specified SCSI IDs. This is done through the SCSI configuration menu.
Target ID's enabled for the PowerVault 35F must be unique on the SCSI bus, with the exception that the initiator ID
used on the PowerVault 35F should also be used as a single target ID. For example, in SCSI-to-Fibre Channel mode,
one of the targets must have the same ID as thePowerVault 35F.
NOTE: The initiator and target ID's must be assigned before the address table can be configured.
Back to Contents Page
file:///C|/Users/rishi_sood/Desktop/35F/ug/config_1.htm[3/21/2013 11:16:19 AM]
AL_PA
LUN
0xEF
0
0x02
0
0x04
0
0x08
0
0x0F
0
0x10
0
0x17
0
0x18
0