Step Three: Make Add-On Air Proving Decision - Honeywell HCM-631N - Quietcare 3 Gallon Owner's Manual

User guide
Table of Contents

Advertisement

STEP THREE:
Make Add-On Air Proving Decision
In addition to monitoring system power and fan regulation, TrueSTEAM can monitor physical air movement
through an optional add-on air proving device. If an air proving device is added, TrueSTEAM can create steam
only if the fan is moving air through the supply duct.
IMPORTANT NOTE: The images below are not a complete wiring diagrams. It only depicts power monitoring
and is not meant to be a stand alone diagram. Please refer to the "Wiring the TrueSTEAM" section in the
following pages for complete wiring diagrams.
TrueSTEAM
R
C
1
2
3
4
5
On
Off
32
R
C
6
WIRING BASICS
HVAC System
Wire TrueSTEAM R and C to HVAC system
R and C with an air proving device in-line
on C.
Configure air proving through DIP 5 on
TrueSTEAM. Set DIP 5 up and keep
DIP 4 down.
TrueSTEAM will look for physical air
movement through its C connection before
steam enters the duct.
M29619
TrueSTEAM Humidification System 69-2285—01

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Truesteam

Table of Contents