Parts List; Setting The Ventilation Control - Honeywell DH90A1015 - TrueDRY t Dehumidifier Installation Manual

Whole house dehumidifier with fresh air ventilation
Table of Contents

Advertisement

DH90 Dehumidifier • For HVAC Installer Only
Figure 8: Wiring DH90 with VisionPRO IAQ.
FIELD INSTALLED
JUMPER BETWEEN
DHM 1 AND VNT 1
BLUE - DEHUMIDIFIER AND FAN OPERATION
DH90
YELLOW - 24V POWER
GREEN - FAN OPERATION ONLY
RED - 24V COMMON
WHITE - COMMON

7. Parts List

For replacement parts contact your installing
contractor.
Part Number
Description
DH90A1007
90-Pint Dehumidifier with H8908C
Manual Dehumidistat Control
DH90A1015
90-Pint Dehumidifier with YTH9421
VisionPRO® IAQ Total Home Comfort
Thermostat with Auto/Manual Humidity
Control
EARD6
Motorized Damper
50018994-001
14" x 14" x 1" MERV 11 Filter
50018995-001
10" Back Draft Damper
H8908C1000
Manual Dehumidistat Control
YTH9421C1002 VisionPRO® IAQ Total Home Comfort
Thermostat with Auto/Manual Humidity
Control

8. Setting the Ventilation Control

1. Be sure power is turned on.
2. Set the Ventilation Standard on the control.
3. Set the bedrooms dial.
4. Set the area (sq ft) dial.
5. Set the airflow (cfm) dial.

1
2
3
C
24 VAC
R
RC
RH
H1
U
M2
D1
H
OR
M2
V1
N
T2
FRESH
AIR
DAMPER
M23624
6. Press the test button and observe the lights:
green light is flashing.
The dial settings meet the chosen standard.
Red light is flashing.
There is not enough fresh air delivered
to meet the requirements of the selected
standard. See Troubleshooting section.
7. Record settings on the label inside the cover
as shown in the diagram.
TIPS:
Ventilation control reads new dial setting only
when test button is pushed or power is cycled.
To ensure dial settings are read, push test
button after any changes are made.
For single bedroom homes, set the bedrooms
dial to 2 (this may result in more ventilation than
the minimum required).
For homes having more than five bedrooms
and only a single ventilation system, set the
bedrooms dial to 5 (this may result in less
ventilation than the minimum required).
For conditioned square feet, set area (sq ft) dial
to the nearest value.
For airflow, set airflow (cfm) dial to the nearest
value.
Vaulted ceilings do not need to be considered
when setting this control.
For homes with multiple systems: Honeywell
recommends a ventilation control and fresh
air intake for each system. Measure ventilation
airflow for each system independently. Refer to
Multi-system Setup Example for further details.
W8150A 1001
Date installed:________________________
Ventilation Limit*
G
R
24 VAC
F
R
C
60%
1
100%
C
XFRM
HVAC
C
DMP
ASHRAE 62.2
2
62-1999
C
Damper
C
H
DMP
Ventilation
Installer
Standard
Test
W
AUX
ERV/Fan
Stat
G
AUX
T
REM
Timer/Switch
_________
_________
_________
REM
bedrooms
area (sq. ft.)
airflow (cfm)
Record settings above
Honeywell
Golden Valley, MN 55422
www.honeywell.com/yourhome
Para español ver las instrucciones
50001159-001 Rev. A
or call 1-800-468-1502
*See Instructions
Voir mode d'emploi en français inclus
W8150A 1001
G
R
24 VAC
F
R
C
XFRM
C
ASHRAE 62.2
HVAC
C
DMP
C
Damper
C
DMP
H
W
AUX
ERV/Fan
Stat
G
AUX
T
REM
Timer/Switch
REM
Date installed:________________________
Ventilation Limit*
60%
1
100%
2
62-1999
Ventilation
Installer
Standard
Test
_________
_________
_________
bedrooms
area (sq. ft.)
airflow (cfm)
Record settings above

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dh90Dh90a1007Dh90a1015Dh90a1015/u

Table of Contents