9.0
S
RAID
OFTWARE
It is possible to use software RAID for striping or mirroring multiple X8 Accelerator devices.
Note that X8 Accelerator devices have embedded flash-aware RAID with 7+1P redundancy that provides protection against bad blocks
and flash component failures. This reduces the need for mirroring X8 Accelerator devices in some usage scenarios.
The default software RAID creation parameters are sufficient for good read and write performance.
Below is an example of creating a striped volume across two X8 Accelerator devices:
#mdadm --create /dev/md0 --level=0 --raid-devices=2 /dev/vgca0 /dev/vgca1
10.0 M
ANAGEMENT
10.1
vgc-monitor
vgc-monitor utility allows monitoring of X8 Accelerator device status and health. When called without parameters, it lists all
Seagate X8 Accelerator devices in the system with their configuration and health summary.
Command syntax:
#vgc-monitor --help
vgc-monitor: 3.2.55402.C7
Utility to monitor Seagate X8 Accelerator drives
Usage:
vgc-monitor [-d|--drive <drive-name>]
vgc-monitor [-h|--help]
Options:
-d | --drive : drive name vgc[a,b,---]. display info for the given drive
-h | --help : display this help and exit
no arguments: display info for all drives
Example. Detailed output for vgca drive:
S
X8 A
EAGATE
CCELERATOR
U
TILITIES
U
G
L
, R
SER
UIDE FOR
INUX
EV
. A
12