Figure 12 Aruba 650 — Top view
Figure 13 Aruba 650 — Bottom view

Applying TELs

The Crypto Officer is responsible for securing and having control at all times of any unused tamper evident
labels. The Crypto Officer should employ TELs as follows:
Before applying a TEL, make sure the target surfaces are clean and dry.
Do not cut, trim, punch, or otherwise alter the TEL.
Apply the wholly intact TEL firmly and completely to the target surfaces.
Ensure that TEL placement is not defeated by simultaneous removal of multiple modules.
Allow 24 hours for the TEL adhesive seal to completely cure.
Record the position and serial number of each applied TEL in a security log.
Once the TELs are applied, the Crypto Officer (CO) should perform initial setup and configuration as
described in the next chapter.