c. Slide the spacer and small washer onto the axle next to the
wheel.
d. Slide the partially assembled axle through the wheel support
frame.
e. Slide the small washer and spacer onto the axle next to the
wheel support.
f. Slide the wheel then large washer onto the axle and hold in
place with the remaining cotter pin.
g. Install the caps over the larger washers to finish the wheel
assembly.
2.
To install handle bars 1 and 2 as shown below in the
drawing, slide the handle loop tops (the two pieces with
the cord wraps) into the handle bases. Make sure the cord
wraps are on the opposite side of the control panel.
Depress the spring-loaded locking buttons on each leg and
slide onto base until locked in place.
3.
Follow Step 2 to attach the wheel support base (the one
piece without a cord wrap).
Enerco Group, Inc. | Kerosene Forced Air Heater
PREPARING FOR OPERATION
1.
Check the heater for possible shipping damage. If any is
found, immediately contact the manufacturer at
800-251-0001.
2.
Follow all of the "Precautions".
3.
Fill the fuel tank with clean kerosene, JP8 Jet Fuel, #1/#2
Diesel, or #1/#2 Fuel Oil. In extremely cold weather,
condensation may develop in the tank and it is recommended
that a tablespoon of de-icer be added for each gallon (4
liters) of fuel in the tank. When filling the heater, use at least
2 gallons (8 liters) of fuel. Be sure heater is level and do not
overfill. Use a funnel or can with a long fill spout.
IMPORTANT: Before filling fuel tank the first time or after
extended storage periods, drain the fuel tank of any
moisture or condensation.
4.
Locate heater at a safe distance from combustible
materials. Model TS75KT is not suitable for use on wood
floors or other combustible materials. When used, the
heater should rest on suitable insulating material at least 1
inch thick and extending 3 ft. or more beyond the heater in
all directions.
START
1.
Make sure the "ON/OFF" switch is "OFF". Plug heater into
a grounded 115V, 60 Hz, 1 Ø outlet. Start heater by push
toggle switch to "On" position (light signifies switch is in
"ON" position). If room temperature is greater than 77
you will need to increase thermostat setting to start heater.
Adjust thermostat to desired setting. Heater will cycle on/
off as heat is required.
For all models: In cold weather, starting may be improved by
holding a finger over the vent hole of the pump adjustment
screw cap until the heater starts. This unit is equipped with an
interrupt circuit. The reset is located near the power cord. If the
unit does not start, press the reset button.
STOP
Push "On/Off" switch to "Off" position. For extended
1.
shutdown, unplug heater from power source.
RESTART AFTER DIAGNOSTIC SAFETY SHUTDOWN
(See page 7)
Wait 5 minutes.
1.
2. Press reset button.
5