General Information; For Safe Operation - Mr. Heater MH26TC Operating Instructions And Owner's Manual

Gas-fired infra-red portable heater
Table of Contents

Advertisement

1. general inFOrMatiOn

A. The Mr. Heater MH26TC is a high pressure propane
appliance and is designed to be connected to a bulk
propane cylinder. Every unit is tested during manufactur-
ing and shipped fully assembled except as noted.
b. Intended use of this heater is primarily the temporary
heating of buildings under construction, alteration or
repair.
C. Installation of heater must conform with local codes
or in absence of local codes, with the Standard for the
Storage and Handling of Liquefied Petroleum Gases,
ANSI / NFPA 58 latest edition. Natural Gas and Propane
Installation Code, CSA B149.1;
D. This heater is equipped with two automatic Safety
Shutoff Valves. The gas flow will automatically stop to a
heater burner if the heater burner fails to operate.
E. Maximum safety and convenience have been built into
the Hi-Med-Lo Control Valve/Regulator. The following
table lists the approximate BTU's consumed and the
operating hours you can reasonably expect from bulk
propane cylinders.
Burners
Valve
Operating
position
1
Hi
1
Med
1
Lo
2
Hi
2
Med
2
Lo
Figure 1.
F. 12 P.S.I. minimum inlet gas supply pressure for the pur-
pose of input adjustment.
G. Maximum inlet supply pressure is 120 P.S.I.
H. Heater area to be kept clear and free from combustible
materials, gasoline, and other flammable vapors and
liquids.
I. Flow of combustion and ventilation air must not be
obstructed.
J. The heater should be inspected before each use and at
least annually by a qualified service person.
K. Hose assembly shall be visually inspected prior to each
use of heater. If it is evident there is excessive abrasion
or wear, or the hose is cut, it must be replaced prior to
the heater being put into operation. Replacement hose
assembly shall be Mr. Heater hose assembly as listed in
the parts list.
L. When heater is not in use, turn off the LP gas supply at
the LP gas cylinder.
M. See your local dealer or contact Mr. Heater Corp. for re-
placement parts or information pertaining to this heater.
Generic part replacement may also void your warranty.
N. The minimum ambient temperature rating for this heater
is 20°F.
Mr. Heater | MH 26TC Gas-Fired Infra-Red Portable Heater
Btu
cylinder
input
20 lb.
13,000
32 hours
11,500
37 hours
10,000
42 hours
26,000
16 hours
23,000
18 hours
20,000
21 hours

2. FOr saFe OperatiOn

A. read instructiOns careFullY: Read and adhere to
these instructions. Do not allow anyone who has not read
the instructions to assemble, light, adjust or operate the
heater.
warning:
Keep the heater out of the reach of children.
b. prOpane is VerY FlaMMaBle: In the event of a leak,
propane will accumulate and the possibility of a fire is pres-
ent. Propane gas is scented and its strong odor is readily
detectable. Never strike a match or bring any flame or
create an electric spark in an enclosure when you smell pro-
pane gas. Ventilate the area thoroughly, move the heater
outside, find and correct the source of the leak before at-
tempting to light any appliance. If you are unsure of these
instructions evacuate immediately and call for help.
C. gas leaKage: If the leak cannot be corrected, do not
tamper with the heater, follow the shut down instructions
and return the heater to the dealer or address given on
front page.
warning:
Do not use this heater on bulk tanks of greater capacity
than 20 pounds LPG (50 pounds water capacity).
D. leaK detectiOn: Before each use of the heater check
all fittings and connections with a soap solution to be sure
there are no leaks. Be sure the POL fitting is wrench (7/8")
tightened into the on-off valve on the propane cylinder.
neVer, neVer use anY FlaMe FOr leaK test.
E. cOnnecting Heater tO prOpane cYlinder: Always
connect the heater to the bulk cylinder in the outdoors
or in a well ventilated area. Use a 7/8" open end wrench.
NEVER connect this heater to a cylinder near an open
flame.
F. use OF Heater: Always operate the heater with the
propane cylinder in an upright position on a level non-com-
bustible surface. NEVER place the cylinder on its side when
operating the heater.
G. attend Heater: Do not leave heater unattended while it
is in operation.
H. alwaYs use a MatcH tO ligHt Heater: NEVER at-
tempt to light the heater with a spark lighter.
I. dO nOt taMper: Should the heater not perform prop-
erly, such as little or no heat when operating in the "Hi"
position, or for any other reason, dO nOt atteMpt tO
repair Or taMper with the heater. Any tampering could
make the use of the heater unsafe and dangerous. Return
the heater to the dealer or the address given on front page
for repair or replacement.
J. FOr stOrage: The heater Hi-Med-Lo-Off regulating valve
should always be turned to "off" when the heater is not in
use. Allow at least 15 minutes for cooling before handling
3
Operating Instructions and Owner's Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents