This is a copy of the label that accompanies
each Regency Large Freestanding Woodstove
(F3100L).
LISTED SPACE HEATER, SOLID FUEL TYPE, SUITABLE FOR
MOBILE HOME INSTALLATION
MODEL: REGENCY LARGE FREESTANDING STOVE -
TESTED TO: ULC S627-00 / UL 1482-1998 / UL 737-2000
F3100L WITHOUT
F3100L WITH
AIRMATE SHIELD
AIRMATE SHIELD
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
F3100L
WITH AIRMATE SHIELD
MEASURE
FROM
HEATER
RESIDENTIAL INSTALLATION USING
SINGLE WALL CONNECTOR
SIDEWALL
A 460 mm / 18 in
BACKWALL
B 305 mm / 12 in
CORNER
C 215 mm / 8.5 in
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - MOBILE HOME
SIDEWALL
A 460 mm / 18 in
BACKWALL
B 240 mm / 9.5 in
CORNER
C 255 mm / 10 in
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - RESIDENTIAL CLOSE CLEARANCE
SIDEWALL
A 405 mm / 16 in
BACKWALL
B 240 mm / 9.5 in
CORNER
C 215 mm / 8.5 in
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - ALCOVE
SIDEWALL
G 405 mm / 16 in
BACKWALL
H 240 mm / 9.5 in
MINIMUM CLEARANCE BETWEEN HORIZONTAL CHIMNEY CONNECTOR AND COMBUSTIBLE MATERIALS - 460 MM (18 IN.). CLEARANCE MAY BE
REDUCED BY THE USE OF LISTED PIPE SHIELDS, WALL PROTECTORS OR OTHER MEANS APPROVED BY LOCAL BUILDING OR FIRE OFFICIALS.
COMBUSTIBLE FLOOR MUST BE PROTECTED BY NON-COMBUSTIBLE MATERIAL EXTENDING BENEATH THE HEATER AND TO THE FRONT AND
SIDES AS INDICATED OR TO THE NEAREST PERMITTED COMBUSTIBLE MATERIAL.
FOR USE WITH SOLID WOOD FUEL ONLY. USE OF OTHER FUELS MAY DAMAGE HEATER AND CREATE A HAZARDOUS CONDITION. DO NOT OB-
STRUCT COMBUSTION AIR OPENINGS. OPERATE ONLY WITH FIREBRICKS IN PLACE. OPERATE ONLY WITH DOOR CLOSED - OPEN FEED DOOR TO
FEED FIRE ONLY. DO NOT USE GRATE OR ELEVATE FIRE. BUILD WOOD FIRE DIRECTLY ON HEARTH. DO NOT OVERFIRE - IF HEATER OR CHIMNEY
CONNECTOR GLOWS YOU ARE OVERFIRING. INSPECT AND CLEAN CHIMNEY AND CONNECTOR FREQUENTLY. UNDER CERTAIN CONDITIONS OF
USE CREOSOTE BUILDUP MAY OCCUR RAPIDLY. KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL AWAY FROM HEATER. REPLACE
GLASS ONLY WITH NEOCERAM GLASS.
OPTIONAL COMPONENT: FAN, ELECTRICAL RATING: VOLTS 115, 60 HZ, 2 AMPS, SCREEN DOOR
COMPONENTS REQUIRED FOR MOBILE HOME INSTALLATION: OUTSIDE AIR KIT AND ONE OF THE FOLLOWING DOUBLE WALL CONNECTOR
IN CANADA: LISTED SECURITY MODEL DP, OR OLIVER MACLEOD PRO-VENT PV DOUBLE WALLED CONNECTOR WITH LISTED CHIMNEY SYSTEM:
SECURITY MODEL S2100, ICC EXCEL 2100.
IN USA:
LISTED DOUBLE WALL CONNECTORS SECURITY MODEL DP, SELKIRK MODEL DS, OLIVER MACLEOD PRO VENT PV, SIMPSON DURA
VENT MODEL DVL, GSW SUPER PIPE 6, METAL-FAB DOUBLE WALL. CONNECTED TO ONE OF THE FOLLOWING COMPATIBLE CHIMNEY SYSTEMS
SECURITY MODEL S2100 OR MODEL ASHT, SELKIRK MODEL SSII, OLIVER MACLEOD PRO JET 3103, SIMPSON DURA PLUS, GSW MODEL SC OR
METAL-FAB TEMP/GUARD, AMERI-TEC HS, ICC EXCEL 2100 . USE CHIMNEY COMPONENTS AS SPECIFIED IN INSTALLATION INSTRUCTIONS.
UNITED STATES ENVIRONMENTAL
PROTECTION AGENCY
Regency Freestanding Woodstove
COPY OF SAFETY LABEL FOR F3100L
We have printed a copy of the contents here
for your review.
INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION AND OPER-
ATING INSTRUCTIONS. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND
INSTALLATION INSPECTION IN YOUR AREA. USE 150 MM (6 IN.) DIAMETER MINIMUM 24 MSG BLACK
OR 25 MSG BLUED STEEL CONNECTOR WITH LISTED FACTORY-BUILT CHIMNEY SUITABLE FOR USE
WITH SOLID FUELS OR MASONRY CHIMNEY.
SEE LOCAL BUILDING CODE AND MANUFACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED
FOR PASSING A CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING. DO NOT PASS CHIMNEY
CONNECTOR THROUGH COMBUSTIBLE WALL OR CEILING. DO NOT CONNECT THIS UNIT TO A CHIM-
NEY FLUE SERVING ANOTHER APPLIANCE.
F3100L
WITHOUT AIRMATE SHIELD
FLUE
MEASURE
CENTER-LINE
FROM
HEATER
RESIDENTIAL INSTALLATION USING
SINGLE WALL CONNECTOR
D 810 mm / 32 in
SIDEWALL
A 510 mm / 20 in D 860 mm / 34
BACKWALL
B 355 mm / 14 in E 520 mm / 20.5 in
E 470 mm / 18.5in
CORNER
C 265 mm / 10.5in F 610 mm / 24
F 560 mm / 22 in
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - MOBILE HOME
D 810 mm / 32 in
SIDEWALL
A 510 mm / 20 in
E 405 mm / 16 in
BACKWALL
B 305 mm / 12 in
F 595 mm / 23.5in
CORNER
C 255 mm / 10 in
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - RESIDENTIAL CLOSE CLEARANCE
D 760 mm / 30 in
SIDEWALL
A 510 mm / 20 in
E 405 mm / 16 in
BACKWALL
B 305 mm / 12 in
F 560 mm / 22 in
CORNER
C 215 mm / 8.5 in
ALCOVE INSTALLATION
I 760 mm / 30 in
REQUIRES AIRMATE SHIELD
J 405 mm / 16 in
MANUFACTURED BY:
CAUTION
HOT WHILE IN OPERATION DO NOT TOUCH. KEEP CHILDREN,
CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE
SKIN BURNS. READ NAMEPLATE AND INSTRUCTIONS.
NOTE: Regency units are constantly being
improved. Check the label on the unit and if
there is a difference, the label on the unit is the
correct one.
102
DO NOT REMOVE THIS LABEL
102
F3100L
REPORT NO.6623 (MAY 93)
FLUE
CENTER-LINE
in
in
D 860 mm / 34 in
E 470 mm / 18.5 in
F 595 mm / 23.5 in
D 860 mm / 34 in
E 470 mm / 18.5 in
FLOOR
F 560 mm / 22 in
PROTECTION*
K
405 mm / 16 in
L
150 mm / 6 in
M
150 mm / 6 in
* In Canada, fl oor protection must
extend 18" to the front and 8" to
each side of the stove.
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.
6988 VENTURE ST.
DELTA, BC V4G 1H4
CERTIFIED TO COMPLY WITH JULY 1990,
PARTICULATE EMISSION STANDARDS.
SAFETY LABEL
MADE IN CANADA