Viking BLK-3-EWP Technical Practice page 3

Line status strobe light kit with ewp
Hide thumbs Also See for BLK-3-EWP:

Advertisement

B. Front Mounting Without Weatherproof Box
The BLK-3-EWP Strobe Light Kit may be mounted with-
out using the included weatherproof box. To mount the
strobe light from the front, use the diagram below.
Strobe Light
(included)
(2) #8-32 x 2 1/2 Phillips
Head Self Tapping Screws (included)
P
r
o
g
r
a
m
m
P
r
o
g
r
a
m
m
A. DIP Switches
Description
Sw 1
Sw 3
Ring Detection Only (see section B).
ON
OFF
Off-Hook/Loop Current Detection Only (see section B).
OFF
ON
Ring and Off-Hook/Loop Current Detection (see section B).
ON
ON
Sw 2
Ring Cadence Mode (see section C)
ON
Ring Cadence Mode ON - relay remains activated in between rings.
OFF
Ring Cadence Mode OFF - relay is activated only during ringing.
B. Configuring for Ring and/or Loop/Off-Hook Indication
Note: The phone and
incoming line connec-
tions are NOT polarity
sensitive.
Incoming
Analog
Phone Line
Phone or
Terminal Device
(not included)
1. Ring Indication Only
Connect the incoming line to the red and green wires with the yellow stripe as shown in the diagram. No phone/terminal device
is required. The LDB-3 control module can monitor for ringing any place along the ringing line.
2. Loop/Off-hook Indication Only
The LDB-3 control module must be placed between the phone line and the phone/terminal device to be monitored. Connect the
incoming line to the red and green wires with the yellow stripe and connect the phone/terminal device to the brown and gray
wires as shown.
3. Both Ring and Loop/Off-hook Indication
If the application requires ring and loop/off-hook indication, the LDB-3 control module must be placed between the phone line
and the phone/terminal device to be monitored. Connect the incoming line to the red and green wires with the yellow stripe, con-
nect the phone/terminal device to the brown and gray wires.
C. Ring Cadence Mode
DIP switch 2 is used for switching between different ring detection modes. In the OFF position, the relay and switched 12VDC out-
put will activate only while ring voltage is present and will turn off between rings. In the ON position, the relay and switched 12VDC
output will remain on for up to 5.75 seconds after the ringing has stopped. This allows the relay and 12VDC (flashing strobe light)
to remain on between rings of a standard ring cadence. Note: To use the Ring Cadence Mode, ring detection MUST be enabled
(DIP switch 1 - ON).
Wall, post, etc.
2.75"
Red
Black
i
n
g
i
n
g
* Gel-Filled Butt
Connectors (included)
120V AC
Note: Polarity Sensitive!
12V DC
(+) Red with
Adapter
(+) Black
Black stripe
Included
(-) Black with
(-) Black with
White stripe
White stripe
Yellow stripe
Green with
Yellow stripe
Brown
Gray
C. Rear Mounting Without Weatherproof Box
To mount the strobe light from the rear, use the
diagram below.
(2) #10-32 x 5/8
Phillips Head Self
Tapping Screws
To LDB-3
Control
Module
(included)
LDB-3 Control Module
(included)
S1
Red with
Blue
Blue
Disable Feature (see
Programming section F)
Strobe Light
(included)
(included)
Red
To LDB-3
Control
Black
Module
(included)
1
ON
2
3
* Note: The gel-filled (water tight) butt connectors
are designed for insulation displacement. Do not
strip wires prior to terminating.
Rear View of the
Strobe Light (included)
* Gel-Filled Butt
Connectors
(included)
Red (+)
Red (+)
Black (-)
Black (-)
Orange
N.C.
Purple
COM.
Contact Output
Yellow
N.O.
11
10
9
8
7
6
5
4
3
2
1
Auxiliary