Frymaster BK1814 Series Installation & Operation Manual page 37

Gas fryers
Table of Contents

Advertisement

5.5.2 Filter Operation (cont.)
9. After all oil is pumped back into the frypot,
bubbles will form, indicating air in the oil
return lines. Allow the oil to bubble for 10-
15 seconds to ensure all oil is evacuated
from the return lines.
handle to close the oil return valve and
deactivate the filter pump (see Step 5 above
for additional reference).
10. If the oil level is low, add oil until the level
is at the top OIL LEVEL line.
DO NOT OVERFILL THE FYPOT. This
will cause oil to splash out of the
frypot during cooking and may
cause burns or damage.
11. Replace the frypot grid, using care not to
splash hot oil. Turn the fryer on.
Frymaster BK1814 Series Gas Fryers
Chapter 5: Filtration Operation
Turn the yellow
5-11
Allow the oil to bubble for 10-15 seconds to
ensure evacuation of all oil in the return lines.
Add oil until the oil level is at the top OIL LEVEL
line. DO NOT OVERFILL THE FRYPOT.
Replace the frypot grid, using care not to splash
hot oil.