9-1-2 : Abnormal initial operation (Normal +4.0V voltage source)
Press PWR KEY
32KOUT is
C671 voltage level
= 1.1~1.3V?
C673 voltage level
= 1.8V?
TR501 pin3
output is aserted?
U401 pin4
output is aserted?
exit?
YES
YES
YES
YES
YES
END
SAMSUNG Proprietary-Contents may change without notice
This Document can not be used without Samsung's authorization
Check OSC600 and
NO
neighboring circuits
NO
Check L600 and
neighboring circuits
NO
Check L608 and
neighboring circuits
NO
Check TR501
and neighboring circuits
NO
Check U401
and neighboring circuits
9-3