FAUCET ASSEMBLY INSTALLATION
•
Attach faucet knob (9) to Faucet & Shank Assembly (6).
•
Slip the Faucet & Shank Assembly (6) through the black
plastic collar (7) (flat side toward door), Facade (3), and
hole in door.
•
Thread on the large Shank Nut (8) and tighten until snug,
using an adjustable wrench. DO NOT over tighten.
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION
Replacing the faucet knob (9) with a longer knob is not
recommended. This may interfere with the opening of the
freezer door causing beverage spillage and/or damage to
the faucet assembly and door.
SUMP AND DRIP TRAY ASSEMBLY INSTALLATION
•
Remove bottom mounting screw.
•
Align the two notched mounting tabs on back of sump (1)
with upper mounting screws in door and push up.
•
Install bottom mounting screw through slot and tighten.
FIRST STEPS (continued)
SUMP VALVE INSTALLATION
•
Place one rubber washer (5) on threaded end of sump
valve (4).
•
Slip sump valve with washer through hole in bottom of sump
(1).
•
Place remaining rubber washer (5) over threaded end of
sump.
•
Thread plastic nut (5) onto threaded end of sump valve and
tighten until snug.
•
Make sure knob on valve is located to front for proper
operation.
•
Place Drip Tray (2) onto the Sump (1).
REGULATOR INSTALLATION
•
Check to ensure plastic washer is inside the hex nut.
N O T E
N O T E
N O T E
N O T E
N O T E
If the plastic washer is missing, please call Electrolux
Consumer Services at 1-800-944-9044 for assistance
•
Fasten the CO
the regulator to the right of the tank.
•
Tighten the hex nut securely. DO NOT over tighten. Over
tightening may damage the gasket in the nut of the regulator.
9
regulator (10) to the CO
canister (16). Place
2
2
.
Need help?
Do you have a question about the 241666500 and is the answer not in the manual?
Questions and answers