Minimum Flame Adjustment - AEG 79902 Operating Instructions Manual

Electronic gas hob
Table of Contents

Advertisement

4. Touch the Decreasing Control
the required type of gas.
5. After selecting the type of gas, switch off
the hob touching the main ON/OFF Control
.
6 . Touch the main ON/OFF Control
again
to reactivate the hob.
The appliance is automatically set to the
normal "User Mode".
7. Light all the burners and adjust their flame
to minimum, in order to check the flame
stability (visual check).
8. At the same time, check the flame aspect
(visual check).
If both the flame stability and the flame aspect
are satisfactory, the setting of the hob for the
new gas type is completed.
If the flame stability is not satisfactory, carry out
an additional adjustment as described in the
following paragraph.

Minimum flame adjustment

If the flame stability and the flame aspect
are not satisfactory, proceed as follows:
1. Carry out the steps described in the
paragraph "Setting the hob for the new gas
type" - points 1, 2 and 3.
2. Light the burner to be adjusted following
the instructions given in the paragraph
"How to light a burner".
The burner is automatically set to the
minimum flame level.
3. If the flame minimum level is too low, the
burner extinguishes. The hob automatically
carries out a minimum level adjustment and
then relights the burner.
to select
35

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

79902g

Table of Contents