What Can You View; Output Jumper Selections; Millivolt Input Option Jumper Selections - Omega DPF78 SERIES User Manual

Rate/totalizer
Table of Contents

Advertisement

1) "A sub B" - If you have selected the "A sub B" mode, pressing "view" shows:
A) The net result of subtracting input B from input A. Pulses on input B will subtract (count down). Pulses on input A
will add (count up) if "reset to 0" is selected, if "set to preset" is selected, input A will subtract (count down).
B) The rate of input A.
2) "A add B" - If you have selected "A add B" mode, pressing "view" shows:
A) The net result of adding "A" and "B" inputs. Pulses on input B will add (count up). Pulses on input A will add
(count up) if "reset to 0" is selected, if "set to preset" is selected input A will subtract (count down).
B) The rate of input A.
3) "A sep B" - If you have selected " A sep B" mode, pressing "view" shows:
A) The total counts of input A. If "reset to 0" is selected A counts up, if "set to preset" is selected A will count down.
B) The rate of input A.
C)* The total counts of input B. B will always count up.
NOTE: In "A sep B" mode, B can be used in 3 ways:
1) As a separate totalizing counter
2)** As a Batch Total Counter for input A
3)** As a Grand Total Counter for input A
NOTE:
* All decimal points are inverted when "B total" is being displayed.
** See below on how to modify for Batch Count and "B" as a Grand Total Counter.

OUTPUT JUMPER SELECTIONS

FUNCTION
"A" RELAY
N.C. OUTPUT
"B" RELAY
N.C. OUTPUT
*
"A" PRESET
TRANSISTOR (NPN)
*
"B" PRESET
TRANSISTOR (NPN)
"B" AS BATCH
COUNTER
"B" AS GRAND
TOTAL COUNTER
BOTTOM VIEW AT TERMINAL
L
20192
12 11 10 9 8 7 6 5 4 3 2 1
* The unit must be removed from the case to access jumpers C & F, all
other jumpers can be accessed by removing the plastic extender.
NOTE: All three pads at jumpers 2 and 4 are connected.

WHAT CAN YOU VIEW?

MODIFICATION
CUT
JUMPER
AT "A"
"B" TO "2"
CUT
JUMPER
AT "D"
"E" TO "4"
CUT
JUMPER
AT "A"
"C" TO "2"
CUT
JUMPER
AT "D"
"F" TO "4"
SELECT
JUMPER
"A SEP B" "H" TO "G"
SELECT
CONNECT
"A SEP B" PULSES TO
"A" & "B"
F
C
E
D
B
A
H
G
4
2
MILLIVOLT INPUT OPTION
JUMPER SELECTIONS
C7
U2
R2
C3
R1
CR2
R3
CR5
CR4
R10
C6
CR1
R9
R8
R4
R5
R7
C8
U5
If the unit has the millivolt input bd.# 20229, A & B inputs can be
separately solder jumper programmed to accept either a low milli-
volt or 4-30 V input. Each unit shipped is programmed according
to part number. If solder jumpers are made, the part number
should be modified to reflect the changes made
C=CLOSE, O=OPEN
4-30V INPUT
Input A
J1-O, J2-C, J3-O
InputB
J4-O, J5-C, J6-O
5
U1
J6
C5
U4
J5
J4
C1
C9
C2
C4
REV
B
P1
R6
CR6
20229
U3
CR3
Millivolt INPUT
J1-C, J2-O, J3-C
J4-C, J5-O, J6-C
J3
J2
J1