Handling With Modules; Download Of New Blocks Or Delta Downloads; Uploading Blocks - Siemens Simatic S7-300 Technical Data Manual

Cpu 31xc and cpu 31x
Hide thumbs Also See for Simatic S7-300:
Table of Contents

Advertisement

Memory concept
4.2 Memory functions
Note
This function is only permitted when the CPU is in STOP mode. Load memory is cleared if
the load operation could not be completed due to power loss or illegal block data.
4.2.3

Handling with modules

4.2.3.1

Download of new blocks or delta downloads

There are two ways to download additional user blocks or download deltas:
• Download of blocks: You already created a user program and downloaded it to the CPU
• Delta download: In this case, you only download the deltas in the blocks of your user
The data of dynamic blocks are transferred to RAM and activated after the block is
downloaded.
4.2.3.2

Uploading blocks

Uploading blocks
Other than download operations, an upload operation is the transfer of specific blocks or a
user program from the CPU to the PG/PC. The block content is here identical with that of the
last download to the CPU. Dynamic DBs form the exception, because their actual values are
transferred. An upload of blocks or of the user program from the CPU in STEP 7 does not
influence CPU memory.
4-12
via MMC. You then want to add new blocks to the user program. In this case, you do not
need to reload the entire user program to the MMC. Rather, you can download only the
new blocks to the MMC (this reduces download times for highly complex programs).
program. In the next step, perform a delta download of the user program, or only of
changed blocks to the MMC, using the PG/PC.
Warning
The delta download of blocks / user programs overwrites all data stored under the same
name on the MMC.
CPU 31xC and CPU 31x, Technical data
Manual, Edition 08/2004, A5E00105475-05

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents