Model #: SU3000RTXLCD3U
SmartOnline 3kVA On-Line Double-Conversion UPS, 3U Rackmount, Interactive LCD display,
100/110/120/127V NEMA outlets
Description
Tripp Lite Smart Online UPS systems offer high performance power protection ideal for critical server and network equipment in datacenters,
computer rooms and network closets. Online, double-conversion Uninterruptible Power Supply (UPS) maintains perfectly regulated output power by
continuously converting raw AC input to DC, then re-converting output back to AC. Fully regulated sine wave AC output with +/-2% voltage regulation
powers network equipment continuously, even during severe brownouts and overvoltages, all without depleting UPS battery reserves. Maintains
battery-derived AC output during power failures with zero transfer time. Extended runtime options available. Interactive LCD interface reports UPS
operating mode, detailed UPS and site-power data, plus enables a variety of UPS setup and configuration options. Highly efficient operation in
optional economy mode saves BTU heat output and energy costs. Network management interfaces support communications via USB, RS-232,
contact-closure and optional SNMPWEBCARD network interface. Built-in DB9 port offers both enhanced RS-232 data and basic contact closure
monitoring ability. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and
Mac OS X. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. LED display reports UPS
operating mode, line power availability, battery mode operation, inverter operation, ECO mode status and output power availability. Audible alarm
with push-button momentary alarm-cancel and silent-mode LCD configuration options. Programmable self-test. Battery independent restart.
Fault-tolerant auto-bypass mode. Field-replaceable, hot-swappable internal batteries and external battery packs.
Package Includes
SU3000RTXLCD3U UPS System
PowerAlert Software with USB, Serial & EPO cabling
4 post rackmount installation kit
Instruction manual
Features
Tripp Lite SU3000RTXLCD3U 3000VA / 3kVA / 2700W on-line, double-conversion 3U rackmount UPS
Selectable 100/110/120/127V output (120V factory preset)
NEMA L5-30P input, 4 NEMA 5-15/20R, 4 5-15R & 1 L5-30R outlets
Two switched 4-outlet load banks support remote reboot or programmable load shedding options
Supports 2% output voltage regulation and zero transfer time in double conversion mode
Economy mode option offers enhanced efficiency, reduced power consumption and lower BTU emissions
11 minutes runtime at 50% load (1350W) and 4 minutes at 100% load (2700W) with internal batteries
BP72V15-2U (limit 1) or BP72V28RT3U (no limit) external battery packs available (some configurations require Tripp Lite's
Configuration
Software)
LCD interface reports operating mode plus 9 selectable screens of UPS data (Load percentage, kW & kVA, Power factor, Input voltage &
frequency, Output voltage & frequency, Battery voltage and charge percentage, Minutes runtime, Capacity remaining and Kw/hr.
consumption)
LCD interface also supports 16 screens of UPS configuration and setup options
Highlights
3000VA / 3kVA / 2700W on-line double-conversion 3U rackmount UPS
100/110/120/127V 50/60Hz output; High efficiency economy mode option
Interactive LCD with 9 selectable screens of UPS and site power data
Expandable runtime, Hot-swap batteries, 26 in / 66cm depth
USB, RS232 & EPO ports, support for SNMP/WEB card option
2 independently switched load banks
NEMA L5-30P input; 4 NEMA 5-15R, 4 5-15/20R & 1 L5-30R outlets
Tripp Lite
1111 West 35th Street
Chicago, IL 60609 USA
Telephone: +(773) 869 1234
E-mail:
saleshelp@tripplite.com
External Battery

Advertisement

loading

Summary of Contents for Tripp Lite SmartOnline SU3000RTXLCD3U

  • Page 1 NEMA L5-30P input; 4 NEMA 5-15R, 4 5-15/20R & 1 L5-30R outlets Description Tripp Lite Smart Online UPS systems offer high performance power protection ideal for critical server and network equipment in datacenters, computer rooms and network closets. Online, double-conversion Uninterruptible Power Supply (UPS) maintains perfectly regulated output power by continuously converting raw AC input to DC, then re-converting output back to AC.
  • Page 2: Specifications

    4 post installation hardware included, Optional 2POSTRMKITHD enables 2 post rack installation Single line TEL / Network surge suppression Electronic bypass maintains utility output during a variety of UPS fault conditions Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement Frequency regulation / conversion mode offers generator-compatible frequency correction or conversion of frequency from 50 to 60Hz or 60 to 50Hz...
  • Page 3 BP72V15-2U (limit 1); BP72V28RT-3U (multi-pack compatible) pack compatibility Expandable Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software, see runtime description manual for details DC system voltage (VDC) Battery recharge Less than 3 hours recharge to 90%...
  • Page 4: Voltage Regulation

    Battery Hot-swappable, user replaceable batteries replacement description VOLTAGE REGULATION Voltage regulation Online, double-conversion power conditioning maintains 2% output voltage regulation during brownouts and description overvoltages Overvoltage Corrects overvoltages to 150V (0-100% load) correction Undervoltage Corrects undervoltages to 100V at full load (90V at 100V nominal) correction Severe Corrects brownouts to 70V (70% load) &...
  • Page 5 UPS / Power 13.2 x 44.4 x 66 Module dimensions in primary form factor (height x width x depth / cm) Rack Height UPS / Power Module weight (lbs) UPS / Power 33.6 Module weight (kg) UPS Shipping 12 x 23 x 33 dimensions (height x width x depth / inches)
  • Page 6: Warranty

    PowerAlert Included software Communications USB and DB9 cabling included cable WatchDog Supports Watchdog application, OS and hard-reboot restart options for remote applications compatibility LINE / BATTERY TRANSFER Transfer time Zero (0 milliseconds) in double-conversion mode; 4 milliseconds economy mode Low voltage 55V at 33% load, 70V at 70% load, 100V at 100% load (90V full load at 100V nominal setting) transfer to battery power (setpoint)
  • Page 7 Copyright © 2013 Tripp Lite. All rights reserved. All trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice. Photos may differ slightly from final products.