Requirements Of The Installation Site; Care; Recycling And Disposal; Appliance - Vaillant atmoCRAFT VK SERIES Operating Manual

Gas heating boiler
Table of Contents

Advertisement

Caution!
Any improper use is forbidden.
The appliances must be installed by a heating engineer,
who is responsible for adhering to the existing
regulations, rules and guidelines.
3.3

Requirements of the installation site

The Vaillant gas heating boilers atmoCRAFT must be
installed in boiler rooms. Ask your heating engineer
which national regulations must be observed.
The entire installation site should be frost-proof.
Observe the specified frost protection measures in
section 4.10 if you are unable to ensure this
requirement.
Note!
It is not necessary to keep a clearance between
the appliance and combustible materials or
components, since at the rated heating power
of the appliance the temperature at the surface
of the housing is always lower than the
maximum allowed temperature of 85 °C.
3.4

Care

• Clean the exterior of your appliance with a damp cloth
and a little soap.
Note!
Do not use scouring or cleaning agents, which
might damage the exterior or plastic controls.
3.5

Recycling and disposal

Both your Valliant atmoCRAFT gas boiler and its
packaging consist mainly of recyclable raw materials.

3.5.1 Appliance

Do not dispose of your Valliant atmoCRAFT gas boiler or
any of its accessories with household waste. Make sure
the old appliance and any accessories are disposed of
properly.

3.5.2 Packaging

Please leave the disposal of the transport packaging to
the qualified servicing company which installed the
appliance.
Note!
Please observe the applicable national legal
regulations.
Operating manual atmoCRAFT
Notes on the installation and operation 3
3.6

Energy saving tips

Installing a weather compensator
Weather compensators regulate the heating supply
temperature according to the outside temperature. No
more heat is created than is required. The designated
heating feed temperature for the corresponding outside
temperature must be set on the weather compensator.
This setting must not be greater than that required by
the design of the heating installation.
The correct setting is normally undertaken by the
heating engineer. The desired heating and set-back
phases (e.g. at night) are automatically turned on and
off using the integrated time programmes.
Weather compensators combined with thermostat valves
are the most economical form of heating regulation.
Reducing the heating system
Reducing the room temperature at night and in your
absence. This is best and most reliably realised using
regulators with customisable time programmes.
At such times, set the room temperature approx. 5 °C
lower than during full heating times. Reduction of more
than 5 °C brings no additional energy saving, because
then increased heating capacities would be needed for
the next full heating period. Only for longer absences,
e.g. holidays, is it worthwhile to further lower the
temperatures. However, in winter, make sure that there
is adequate frost protection.
Room temperature
Set the room temperature only as high as would be
enough for your comfort level. An extra degree would
mean increased energy consumption of about 6%.
Adjust the room temperature according to the purpose
of use of the room. For example, normally, bedrooms or
seldom used rooms are heated to 20 °C.
Setting the operating mode
In warmer seasons, when the apartment needs no
heating, turn the heating to summer mode. The heating
mode is then shut off, however, the device or the plant
remains ready for operation for water heating.
Uniform heating
Often, in an apartment with central heating, only one
room is heated. Through the encapsulation surfaces of
this room, i.e. walls, doors, windows, roofs, floors, the
unheated adjoining rooms are also heated in an
uncontrolled manner, i.e. heat energy is lost
inadvertently. The capacity of the radiator in this one
heated room is obviously not enough for such an
operating mode.
Consequently, the room cannot be heated adequately
and an uncomfortable feeling of coolness prevails (the
same effect is produced when doors between heated
and unheated or partially heated rooms remain open).
This is incorrect saving: The heating is in operation and
still the room temperature is not comfortably warm.
Greater heating comfort and a more practical operating
GB
5