Validity Of The Manual; Ecotec Plus Boilers; Intended Use; General Information - Vaillant ecoTEC plus Instructions For Installation And Servicing

Wall hung open vent condensing boiler
Table of Contents

Advertisement

1 Introduction

Note!
h
Installation and adjustment of the boiler as well as
service, maintenance and repair may only be car-
ried out by a competent person approved at the
time by the Health and Safety executive and in ac-
cordance with the gas safety (installation and use)
regulations 1998.
1.2

Validity of the manual

This installation manual applies exclusively to units with
the following part numbers:
– 0010002460
– 0010002461
– 0010002724
– 0010002725
The part number of the unit can be obtained from the
identification plate.
1.3

ecoTEC plus boilers

The ecoTEC plus boilers are designed to provide central
heating from a fully pumped open-vented or sealed
water system. The central heating water temperature
can be adjusted on the boiler. The domestic hot water
can only be adjusted on the boiler if it is installed with a
Vaillant uniSTOR unvented cylinder and relevant con-
trols. Once the controls are set the boiler operates auto-
matically.
A frost protection programme is also included.
Please read these instructions and follow them carefully
for the correct and economical use of your boiler. These
instructions are applicable to the following ecoTEC plus
boilers, available in Natural Gas. All ecoTEC plus boilers
can be converted to LPG.
Appliance
ecoTEC plus 415
ecoTEC plus 418
ecoTEC plus 428
ecoTEC plus 438
1.4

Intended use

The boiler has been designed for use with a open-vented
central heating system, and comes fully tested and
assembled. The boiler is easily mounted on any internal
wall and can be installed with either a horizontal or ver-
tical RSF (room sealed fan assisted) flue. The boiler uses
a standard flue system (100 mm or 125 mm outside di-
ameter). Flue extensions and additional bends and el-
bows are available for the flue system to increase the
flexibility. If desired, an inhibitor may be used in the sys-
tem. Guidance on the use of inhibitors is contained in
these instructions. The boiler has a built in diagnostic
system which indicates the operational status of the
boiler. This feature provides key information to aid com-
missioning and fault finding. The data badge is fitted to
4
Maximum output
15 kW
18 kW
28 kW
38 kW
the combustion chamber cover of the boiler. See text of
General Requirements for installation requirements or
notes.
The Vaillant ecoTEC plus boiler is a state-of-the-art ap-
pliance which has been constructed in accordance with
recognised safety regulations. Nevertheless, danger to
the life and limb of the user or third parties can still
occur or the appliance or other material assets be im-
paired in the event of improper use.
The unit is not intended for use by persons (including
children) with reduced physical, sensory or mental capa-
bilities, or lack of experience and/or knowledge, unless
they have been given supervision or instruction con-
cerning use of the unit by a person responsible for their
safety.
Children must be watched to ensure that they do not
play with the unit.
The appliances are designed for central heating sys-
tems. Any other use or extended use is considered to be
use other than intended. The user alone bears the risk.
The manufacturer/ supplier is not liable for any result-
ing damage. Intended use includes the observance of
the operating and installation manual and the adher-
ence to the inspection and maintenance conditions.
a
Caution!
Any incorrect use is forbidden. The appliances
must be installed by a competent person ap-
proved at the time by the Health and Safety
Executive, who is responsible for adhering to
the existing regulations, rules and guidelines.
1.5

General information

Thank you for choosing a Vaillant boiler. The information
given in this booklet will enable you to obtain the best
performance from this boiler.
1.5.1

Gas category

The boiler is supplied factory set for use on Natural Gas
(G20). The ecoTEC plus boilers can be field adjusted for
use on LPG (propane G31), see section 6 for instructions
or contact Vaillant Service, 0870 6060 777.
1.5.2

Gas safety (installation and use) regulations

In your own interests and that of safety, it is the Law
that ALL gas appliances are installed by a competent
person approved at the time by the Health and Safety
Executive in accordance with the current issue of the
above regulations.
1.5.3

Gas testing and certification

The boiler is tested and certificated for safety and per-
formance. It is, therefore, important that no alteration is
made to the boiler.
Instructions for installation and servicing ecoTEC plus 0020020828_07