9 Replacing components

10 Recycling and disposal

11 Vaillant service

Note!
h
Only for natural gas:
Carry out the setting only in steps of 1/8 turn.
After each setting wait for approx. 1 Minute
until the value has stabilised.
Only for liquid gas:
Carry out the setting only in very small steps
(approx. 1/16 turn.) After each setting wait for
approx. 1 Minute until the value has stabilised.
• Swing the air inlet pipe upwards again.
• Check the CO
content again.
2
• If necessary repeat the setting procedure.
• Press the "i" and "+" buttons simultaneously.
The "full load mode" is de-activated. Deactivation of
the full load mode if no button is pushed within a
period of 15 minutes.
• Secure the air inlet pipe.
• Re-fit the front cover.
Settings:
CO
content after 5 min.
2
Full load mode with
front cladding closed
CO
content after 5 min.
2
Full load mode with
front cladding removed
Setting for the
Wobbe-Index W0
CO content in full load
mode
Table 9.2 Factory gas settings
64
Natural
Propane
gas (H)
Tolerance
Tolerance
9.2 ± 1.0
10.2 ± 0.5
9.0 ± 1.0
10.0 ± 0.5
15
22.5
< 250
< 250
10 Recycling and disposal
The product development of all Vaillant products takes
into account later recycling and/or the secure scrapping
of each component used. Vaillant factory standards
stipulate strict requirements in this regard. The selection
process for choosing the raw materials takes into
account their recycling properties , the dismantlability
and the separation facility of the component groups. We
also take into account the environmental and health
dangers associated with the recycling and disposal of
non-reusable remnants.
10.1

Unit

The Vaillant ecoTEC consists to a large extent (up to
92 %) of metallic components designed for recycling by
melting down in the steelworks. This gives these parts
almost indefinite reusability. All plastic materials are
marked properly which makes the separation and
sorting more easy when the component group needs to
be recycled.
Unit
10.2

Packaging

Vaillant strives to keep the scope of the transport
packaging for its units to an absolute minimum. When
Vol.–%
selecting the packaging material its subsequent
reusability is taken into account. High quality cardboard
Vol.–%
has been, for many years, a valuable raw material for
the paper and cardboard industry. The EPS components
(Styropor®) are used for protecting the unit during
kWh/m
3
transport. EPS is 100 % recyclable and CFC-free. The foil
packaging and securing straps are made from recyclable
ppm
plastic.
11
Vaillant service
To ensure regular servicing, it is strongly recommended
that arrangements are made for a Maintenance
Agreement. Please contact Vaillant Service Solutions
(0870 6060 777) for further details.