Functional Description - Vaillant ecoTEC plus 937 Instructions For Installation And Servicing

Wall hung room sealed fan assisted condensing boiler with 15 litre shift load power store
Hide thumbs Also See for ecoTEC plus 937:
Table of Contents

Advertisement

2 Unit description, data and dimensions
2.5

Functional description

20
19
18
c
Fig. 2.5 Sequence diagram
Key
1
Exhaust gas
2 Heat exchanger
3 Combustion chamber
4 Water condensate siphon
5 Expansion vessel
6 Operating display
7 Secondary heat exchanger
8 Automatic air vent
9 Pump
10 Pressure relief valve
11 Diverter valve
12 Gas valve
13 Fan
14 Compact thermal module
10
a
b
17
15
14
13
12
16
15 Shift load storage tank electronics
16 storage charging pump
17 Aqua-Sensor
18 Stainless steel storage tank
19 Storage tank insulation
20 Expansion vessel
NTC sensors shift load storage tank
a Storage tank sensor
b Infeed sensor SWT
c Storage tank charging sensor
ecoTEC plus 937 installation and maintenance manual