Refrigeration System Diagnosis Guide - U-Line SP 18 Service Manual

Table of Contents

Advertisement

Section 2 - Troubleshooting

REFRIGERATION SYSTEM DIAGNOSIS GUIDE

System
Suction
Pressure
Condition
Normal
Normal
Overcharge
Higher than
normal
Undercharge
Lower than
normal
Partial
Somewhat
Restriction
lower than
normal
vacuum
Complete
In deep
Restriction
vacuum
No Gas
0 PSIG to 25"
2-2
Suction
Compressor
Line
Discharge
Slightly below
Very hot
room
temperature
Very cold may
Slightly warm
frost heavily
to hot
Warm-near
Hot
room
temperature
Warm - near
Very hot
room
temperature
Room
Room
temperature
temperature
(cool)
(cool)
Room
Cool to hot
temperature
(cool)
Condenser
Capillary
Tube
Very hot
Warm
Hot to warm
Cool
Warm
Warm
Top passes
Room
warm - Lower
temperature
passes cool
(cool) or
(near room
colder
temperature)
due to liquid
Room
Room
temperature
temperature
(cool)
(cool)
Room
Room
temperature
temperature
(cool)
(cool)
Evaporator
Wattage
Cold
Normal
Cold
Higher than
normal
Extremely
Lower than
cold near
normal
inlet - Outlet
below room
temperature
Extremely
Lower than
cold near
normal
inlet - Outlet
below room
temperature
backing up
No
Lower than
refrigeration
normal
No
Lower than
refrigeration
normal