Friedrich D30C Installation & Operating Manual

Friedrich D30C Installation & Operating Manual

115 volts dehumidifier
Hide thumbs Also See for D30C:

Advertisement

Friedrich
ENERGY STAR
(D40C / D50C / D65C)
Installation
&
Operation
Guide
J
IU_
_Ui
DEHUMIDIFIER
MODELS
115Volts • D30C • D40C • D50C • D65C
Register Your Dehumidifier
Model information can be found on the name plate on the front of the
unit behind the condensate bucket.
To register your dehumidifier, complete and mail the enclosed
registration card, or register on-line at www.friedrich.com
(USA only).
For your future convenience, record the model information here.
MODEL NUMBER
SERIAL NUMBER
PURCHASEDATE
920-154-00 (12/04)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the D30C and is the answer not in the manual?

Questions and answers

Summary of Contents for Friedrich D30C

  • Page 1 Friedrich Installation Operation DEHUMIDIFIER 115Volts • D30C • D40C • D50C • D65C Register Your Dehumidifier Model information can be found on the name plate on the front of the unit behind the condensate bucket. To register your dehumidifier, complete and mail the enclosed registration card, or register on-line at www.friedrich.com...
  • Page 2 Inside you will find many properly. Just a little preventive money over the life of your dehumidifier. You'll find many answers to common review our chart of Troubleshooting • Contact the authorized service technician for repair or maintenance of this unit.
  • Page 3: Safety Precautions

    READ ALL INSTRUCTIONS • To prevent injury to the user, others or property damage, the following instructions must be followed. • Incorrect operation due to ignoring instructions will cause harm or damage; the seriousness is classified by the following indications. I_iL WARNING This symbol indicates the possibility of death or serious injury.
  • Page 4 • tt may cause explosion, fire, and burn. • It wilI cause machine failure or electric shock. Dehumidifier • It will cause electric shock or fire. • It may cause fire and electric shock. • Water may enter the unit and degrade the insulation, tt may cause an electric shock.
  • Page 5 90 Ibs (40kg) of weight. CAUTION , It may cause failure of appliance or performance deterioration. • It may damage the dehumidifier or cause other damage or injury. • The dehumidifier must be operated in an enclosed area to be most effective.
  • Page 6 Safety Precautions • Operation • The appearance of the dehumidifier may deteriorate, change color, or develop surface flaws. • This could injure the pet or plant. • Operation without filters wili cause failure. Dehumidifier • Otherwise, it will cause property damage.
  • Page 7: Prior To Operation

    1. Do not touch the metal parts of the unit when removing the filter. Injuries can occur when handling sharp metal edges. 2. Do not use water to clean inside the dehumidifier. leading to possible electric shock. 3. When cleaning the unit, first make sure that the power and breaker are turned off. The fan rotates at a very high speed during operation.
  • Page 8 Instruction SYMBOLS USED IN THIS MANUAL This symbol dehumidifier. This symbol r_Lr*]r i f-1!_ This symbol PARTS WARNING: This appliance wiring regulations. Control panel Front Grille Air Filter Handle Water bucket Dehumidifier alerts you to the risk of electric alerts...
  • Page 9: Electrical Safety

    To minimize the risk of electric shock, use the plug with a standard three-slot grounding wall power outlet. If the power outlet does not include a grounding slot, have a qualified electrician replace the outlet before you use the dehumidifier. Preferred method...
  • Page 10: Temporary Use Of An Adapter

    Temporarymethod "-"" AdapterP,ug_ -Metat Screw WARNING: Never use the appliance with a broken adapter. TEMPORARY USE OF AN EXTENSION CORD We strongly discourage the use of an extension cord due to potential safety hazards. Dehumidifier...
  • Page 11 CONTROL PANEL 1. POWER key --- Pressing this key once turns the dehumidifier "ON" and pressing again turns the dehumidifier "OFF". 2. HUMIDITY CONTROL keys --- Are used to select the desired humidity setting. • A : Used to raise the desired humidity setting.
  • Page 12 The bucket must be replaced in the proper position for the dehumidifier to work. The light will be on and the dehumidifier will not run if the bucket is not in the proper position.
  • Page 13 Do not sit or stand on the dehumidifier. Secure wheels with blocks to prevent unit from falling when installed on a table or shelf.
  • Page 14 Maintenance and Service Your dehumidifier is designed to serve you year- round, tt needs practically no attention. However, you should check your dehumidifier and inspect the coils annually. You may want an Authorized Service Center to perform this annual checkup. (Cost of the inspection is the owner's responsibility.)
  • Page 15: Troubleshooting

    TROUBLESHOOTING The dehumidifier may be operating abnormally when: Dehumidifier does not start Dehumidifier does not dry the air as it should Dehumidifier runs too much Frost appears the coils Fall noise Water on floor Dehumidifier operates continuously Maintenance • Make sure the dehumidifier...
  • Page 16 (defined fol this pulpose filter drier, and all interconnecting tubing) or material within sixty months from date of purchase, System; PROVIDED FRIEDRICH will not pay the cost of diagnosis of the dehumidifier to and from the Service Agency, and the reinstallafion System.

This manual is also suitable for:

D40cD50cD65c

Table of Contents

Save PDF