Solar Controller - Baxi Solarflo Installation Manual

Evacuated tube collector
Hide thumbs Also See for Solarflo:
Table of Contents

Advertisement

Fig. 5
© Baxi Heating UK Ltd 2008
6
4.0

Solar controller

4.1
Technical Data
Housing Material
100% recyclable ABS
Dimensions
L x W x D in mm
175 x 134 x 56
weight
360 g
Ingress protection
IP40 according to VDE 0470
Electrical values
Operating voltage
230/240V ~ 50 Hz
Interference grade
N according to VDE 0875
Max. conductor
cross-section
240V-connections
2.5 mm
Temperature sensor /
temperature range
PTF6 - 25°C to 200°C
PT1000, 1,000 kΩ at 0°C
Test voltage
4 kV 1 min according to
VDE 0631
Switching voltage
230V / 240V
Capability per one
switch output
1A / 230VA for cos j = 0.7-1.0
Total capability of
all outputs
2A / 460VA maximum
Fuse protection
fine-wire fuse 5 x 20mm, 2A/T
(2 amperes, slow)
Features
Menu driven operation
System monitoring
Solar gain measurement
Suitable for flat plate and evacuated tube type collectors
Auxiliary heat source control
Can be used in a number of system configurations see Fig. 27
NOTE: This controller is suitable for S plan and Y plan systems.
However, in the event of an installation having a 'Y' plan boiler
system that is to be controlled by the solar controller, a relay is
required (not supplied).This is available as a Baxi Spares Item,
Code No. 5122765.
2
fine-strand/single-wire

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents