Installation Of Solar Controller - Baxi Solarflo Installation Manual

Evacuated tube collector
Hide thumbs Also See for Solarflo:
Table of Contents

Advertisement

Fig. 24
Hydraulic Station
Solar
differential
controller
Double pole
isolating switch
L
N
E
230V/240V~
Pump
Mains supply
pre-wired
(mounted on
hydraulic station)
© Baxi Heating UK Ltd 2008
Solar panel
sensor
Terminal block
for extending
collector sensor
Cylinder
sensor
10.0

Installation of solar controller

10.1
Appliance installation
Always disconnect from the mains before opening the
controller cover.
The solar controller is designed to be mounted on the front of
the pump station. Alternatively it can be removed from the
insulation and be wall mounted (see panel below). In the case
of wall mounting the pump cable may need to be lengthened.
Alternative mounting option
In the case of wall installation proceed in the
following way:
Drill installation holes according to the dimensions
shown below. Screw in two upper screws up to 6 mm
distance. Open the appliance as described in section 10.2
and hang it onto two screws. Now two lower screws can be
mounted.Tighten all screws. Do not overtighten to avoid
damage to the controller backplate.
126mm
118mm
10.2
Opening the controller
No tools are required to open the controller.The front of the
controller is secured by two latches which engage with the
controller backplate. It can be opened by gently pulling the
lower side edges outwards and then hinged open.
10.3
Electrical connection overview
Always disconnect from the mains before opening the
controller cover.The electrical installation must conform to all
current Wiring Regulations and be carried out by a competent
electrician.
The connection of all electrical cables is to the terminal block
located on the backplate of the controller.The terminals on
the right side of the terminal block are for safety extra low
voltage connections (SELV) (temperature sensors and flow
transmitters).The terminals on the left side of the terminal
block are for 230/240 V~ connections.