14
15
16
17
18
18
Solarflo - Solar Thermal Domestic Hot Water System
Fibre washer
Collector
inlet/outlet connection
2.0
Installation of solar collector
14: Connect the collector panel flow/return pipe
together. Ensure the fibre washer is inserted between
the male and female connections. Support the pipes
when tightening nut.
15: Rotate the clamping piece by 90° so it locates in the
Collector panel locating lip and screw it tight
using a long socket wrench.
16: Attach additional clamping pieces / collectors as
described in points 11-15.
17: Attach the top mounting part on the upper left and
right end of the collector.
Order:
- mounting rail
- hammer-head bolt
- top mounting part
- M8 washer
- M8 nut
18: Connect flexible connection pipes to collector panel
inlet and outlet connections. Ensure fibre washer is
used between connection pipe and connections.

Advertisement